Banner AG4 Series Safety Laser Scanner
Place
Number Meaning
Activity
1003 3
Motor speed not constant after start, time
exceeded.
If reset is not successful, contact customer service
1110 4
Safety outputs or switching function (OSSDs)
cannot be switched, short-circuit with 0 V DC or
+24 V DC.
Check the connection/wiring of the OSSDs.
1110 5
Safety outputs or switching function (OSSDs)
cannot be switched, short-circuit between OSSD1
and OSSD2.
Check the connection/wiring of the OSSDs.
1110 6
Safety outputs or switching function (OSSDs)
cannot be switched, short-circuit with 0 V DC or
+24 V DC.
Check the connection/wiring of the OSSDs.
1111 7
Short-circuit between safety outputs or switching
function OSSD1 and OSSD2
Check the connection/wiring of the OSSDs.
1111 8
Short-circuit of one safety output or switching
function (OSSD) with 0 V DC.
Check the connection/wiring of the OSSDs.
1111 9
Short-circuit of one safety output or switching
function (OSSD) with +24 V DC.
Check the connection/wiring of the OSSDs.
1606 4
Angle error detected, poss. rotation of the sensor
housing; switch-off and reset followed.
If reset is not successful, contact customer service
1607 5
Angle error detected, poss. rotation of the sensor
housing; switch-off and reset followed.
If reset is not successful, contact customer service
1608 8
Motor speed not constant during operation, poss.
rotation of the sensor housing.
If reset is not successful, contact customer service
1608 9
Motor speed not constant during operation, poss.
rotation of the sensor housing.
If reset is not successful, contact customer service
1608 10
Motor speed not constant during operation, poss.
rotation of the sensor housing.
If reset is not successful, contact customer service
1705 1
Signal of a light beam safety device of the window
monitoring below the bottom limit, dirty front
screen.
Clean the front screen
Product Manual
P/N 144924 05/2009
71