Banner AG4 Series Safety Laser Scanner
Place
Number Meaning
Activity
2017 26
Date of the configuration currently being
transferred is older than the date saved in the
Scanner.
Update the PC's date and time setting.
2018 42
Motion Monitoring, error with the speed matrix
transfer.
Start the configuration transfer again.
2018 43
Motion Monitoring, error with the speed matrix
transfer.
Start the configuration transfer again.
2018 44
Motion Monitoring, the right side of a PF does not
match the predefined vehicle width.
Check all parameters in the wizard, calculate the PFs again and start the
transfer again.
2018 45
Motion Monitoring, a PF length does not match the
predefined braking distance of the vehicle.
Check all parameters in the wizard, calculate the PFs again and start the
transfer again.
2018 46
Motion Monitoring, the left side of a PF does not
match the predefined vehicle width.
Check all parameters in the wizard, calculate the PFs again and start the
transfer again.
2018 50
MotionMonitoring, the left side of a PF does not
match the predefined vehicle width.
Check all parameters in the wizard, calculate the PFs again and start the
transfer again.
2201 5
Number of measurements in the scan is too small
because of motor rotation speed error or internal
fuse is defect.
If reset is not successful, contact customer service
2302
1
Error occurred while Scanner was starting.
Sequential error.
2401 13
Reference measurement failed, dust in the device,
as the plug housing or dummy cap not screwed.
Screw the plugs of interfaces X1 and X2.
2401 10
Reference measurement failed; glare from another
light source (905 nm) or rotation speed error.
Scanner
performs reset.
2401 41
Reference measurement failed; glare from another
light source (905 nm) or rotation speed error.
Scanner
performs reset.
Product Manual
P/N 144924 05/2009
73