Banner AG4 Series Safety Laser Scanner
6. Configuration
The AG4Soft configuration software is used to establish the Scanner operating parameters (see the AG4Soft Software Manual).
The Scanner is configured at the factory with the maximum PF and activated start/restart interlock. Configure the Scanner according to the
application.
6.1
Administrative parameters
6.1.1
Safety Laser Scanner name
Settings
•
Max. 20 characters
•
No default value.
6.1.2
Description
The Description parameter contains further information for clearly assigning the Scanner. It can, for example, provide the Scanner’s precise
point of use.
Settings
•
Max. 100 characters
•
No default value.
6.1.3
Start segment output
The Start segment output parameter establishes the angular segment of the measured field that will be displayed first.
Settings
•
Settable value: 0 to 528
•
Default value: 0
For showing 180° use the value 14 as start segment.
For showing 190° use the value 0 as start segment.
6.1.4
Stop segment output
The Stop segment output parameter establishes the angular segment of the measured field that will be displayed last
Settings
•
Settable value: 0 to 528
•
Default value: 528
For showing 180° use the value 514 as stop segment.
For showing 190° use the value 528 as stop segment.
6.1.5
Output resolution
The Output resolution parameter provides the number of measured values per section shown.
52
P/N 144924 05/2009
Product Manual