Method
Action
Result
SET Button
•
Present sensing condition
•
Click the SET rocker button
Threshold Condition Accepted
Displays read "dr SEt" then alternate
"PASS" with % Offset16; Sensor
returns to Adjust mode
Threshold Condition Not Accepted
Displays read "dr SEt" then alternate
"FAIL" with minimum % Offset16 for
sensing condition; Sensor returns to
Adjust mode
Remote Input
•
Present sensing condition
•
Single-pulse the remote input
T
3. Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
Calibration SET
•
Sets a threshold exactly at the presented condition
•
Threshold can be adjusted using "+" and "-" rocker button (Manual Adjust)
A single sensing condition is presented, and the sensor positions a threshold exactly at the presented condition. When a
condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the LO/DO switch setting
(see LO/DO Switch in
Top Panel Interface
on page 4).
Sensor positions
threshold exactly at
the presented condition
Threshold position
adjusted by
Manual Adjust
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Condition
Presented
Figure 8. Calibration SET (Light Operate shown)
Calibration SET and Manual Adjust
Moves switching threshold value up or down to make adjustments
•
Slide Mode switch to ADJ to enter Adjust mode
•
Press "+" to increase; press "-" to decrease
16 See
Troubleshooting
on page 18 for more explanation of the % Offset displayed after the Dark SET method
DF-G1 Expert
™