background image

Specifications

Sensing Beam

660 nm visible red

Supply Voltage

NPN/PNP models: 10 to 30 V dc Class 2 (10% max ripple)
IO-Link models: 18 to 30 V dc (10% max ripple)

Power and Current Consumption (exclusive of load)

Standard display mode: 960 mW, Current consumption < 40 mA at

24 V dc
ECO display mode: 720 mW, Current consumption < 30 mA at 24 V

dc

Supply Protection Circuitry

Protected against reverse polarity, overvoltage, and transient voltages

Delay at Power Up

500 milliseconds max.; outputs do not conduct during this time

Output Configuration

NPN/PNP models: 1 current sinking (NPN) or 1 current sourcing

(PNP) output, depending on model
IO-Link models: 1 push-pull and 1 PNP (complementary outputs)

Output Rating

100 mA max. load (derate 1 mA per °C above 30 °C)
OFF-state leakage current: NPN/PNP models: < 5 

μ

A at 30 V dc;

IO-Link models: < 50 

μ

A at 30 V dc

ON-state saturation voltage: NPN: < 1.5 V; PNP /IO-Link: < 2 V

Output Protection

Protected against output short-circuit, continuous overload, transient

over-voltages, and false pulse on power up

Output Response Time

High Speed: 200 µs; Standard: 500 µs; Long Range: 2 ms; Extra Long

Range: 5 ms

Repeatability

High Speed: 66 µs, Standard/Long Range/Extra Long Range: 100 µs

Construction

Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear

polycarbonate cover

Environmental Rating

IEC IP50, NEMA 1

Operating Conditions

Temperature: 

10 °C to +55 °C (+14 °F to +131 °F)

Storage Temperature: 

20 °C to +85 °C (

4 °F to +185 °F)

Humidity: 90% at +60 °C maximum relative humidity (non-

condensing)

IO-Link Interface

Supports Smart Sensor Profile: Yes
Baud Rate: 38,400 bps (COM2)
Process Data Width: 16 bits
IODD files: Provide all programming options of top panel interface,

plus additional functionality, see the DF-G1 Manual (P/N 161999)

Certifications

Ind. Cont. Eq.

3TJJ

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following

the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture

which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty

does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR

IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR

TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO

EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR

ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR

SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE

PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY,

NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any

obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

DF-G1 Expert

 Dual Display Fiber Amplifier

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Summary of Contents for DF-G1-NS-2M

Page 1: ...n energized or de energized sensor output condition Models Model Outputs Connector1 DF G1 NS 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PS 2M Single PNP DF G1 KS 2M Dual outputs 1 push pull IO Link a...

Page 2: ...ve from a DIN rail 1 Push the DF G1 up on the DIN rail 1 2 Pivot the DF G1 away from the DIN rail and remove it 2 Installing the Fibers Follow these steps to install glass or plastic fibers 1 Open the...

Page 3: ...er needed When connecting coaxial type fiber assemblies to the amplifier install the solid core fiber to the LED emitting port and the multi core fiber to the PD receiving port for most reliable detec...

Page 4: ...en the sensing condition is below the threshold for Window SET the output is ON when the sensing condition is outside the window SET Rocker Button The SET rocker button is a 3 way button The positions...

Page 5: ...vents unintentional programming changes The SET rocker button is disabled during RUN mode except when using Window SET see Window SET on page 10 DF G1 Expert Dual Display Fiber Amplifier Phone 800 894...

Page 6: ...wo Point TEACH Response Speed Standard 500 s Offset Percent 10 Auto Thresholds OFF OFF Delay 0 Disabled OFF One Shot 0 Disabled ON Delay 0 Disabled ON One Shot 0 Disabled Display Readout Numeric ECO d...

Page 7: ...using the LO DO Light Operate Dark Operate switch see LO DO Switch in Top Panel Interface on page 4 Two Point TEACH and Manual Adjust Moves switching threshold value up or down to make adjustments Sl...

Page 8: ...hod Action Result SET Button Move the Mode switch to RUN Display Red Signal Level Green Threshold Remote Input No action is required sensor returns to RUN mode automatically Dynamic TEACH Teaches on t...

Page 9: ...times to confirm Slide Mode switch to RUN to complete operation Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Dynamic TEACH NOTE TEACH Selection...

Page 10: ...condition All other conditions lighter or darker cause the output to change state Sensing window center can be adjusted using and rocker button Manual Adjust Recommended for applications where a produ...

Page 11: ...play shows the sensing window center value 2 seconds after adjustment the GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember Manual adjustments are dis...

Page 12: ...ht SET Sets a threshold a programmable offset below the presented condition Changes output state on any condition darker than the threshold condition Threshold can be adjusted using and rocker button...

Page 13: ...GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Light SE...

Page 14: ...ition causes the output to change state Threshold can be adjusted using and rocker button Manual Adjust Recommended for applications where only one condition is known for example a stable dark backgro...

Page 15: ...e GREEN display will flash 3 times to confirm Slide Mode switch to RUN to complete operation Remember Manual adjustments are disabled when Auto Thresholds are ON Follow these steps to perform a Dark S...

Page 16: ...djust A single sensing condition is presented and the sensor positions a threshold exactly at the presented condition When a condition lighter than the threshold is sensed the output either turns ON o...

Page 17: ...Sensing Condition Method Action Result SET Button Present sensing condition Click the SET rocker button Threshold Condition Accepted Displays read cAL SEt then flashes PASS Sensor returns to Adjust mo...

Page 18: ...fset after SET The Window Dark and Light SET methods will flash a offset on the displays after a PASS or FAIL SET Result Offset Meaning PASS with Offset Displays the offset used for the SET method FAI...

Page 19: ...IODD files Provide all programming options of top panel interface plus additional functionality see the DF G1 Manual P N 161999 Certifications Ind Cont Eq 3TJJ Banner Engineering Corp Limited Warrant...

Reviews: