Sensor positions
threshold midway
between taught conditions
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Darkest Taught
Condition
Lightest Taught
Condition
Position
adjusted by
Manual Adjust
Figure 7. Dynamic TEACH (Light Operate shown)
The Output ON and OFF
conditions
can be reversed by using the LO/DO (Light Operate/ Dark Operate) switch or through the program
interface for the dual output model.
Dynamic TEACH and Manual Adjust
Moves switching threshold value up or down to make adjustments
• Slide Mode switch to ADJ to enter Adjust mode
• Press "+" to increase; press "-" to decrease
◦
GREEN display shows the switching threshold value
◦
2 seconds
after
adjustment, GREEN display will
flash
3
times
to
confirm
• Slide Mode switch to RUN to complete
operation
Remember: Manual adjustments are disabled when Auto Thresholds are ON
Follow these steps to perform Dynamic TEACH:
Note: TEACH
Selection
must be programmed to dYn tcH.
1. Enter Adjust Mode.
Method
Action
Result
SET
Button
8
Set Mode switch to ADJ
Display: Red - Signal Level; Green -
Threshold
Remote Input 9
No
action
required; sensor is ready for
Dynamic TEACH method
2. Enter Dynamic TEACH.
Method
Action
Result
SET
Button
Click the SET rocker
button
Display: Flashes "dYn tch" then holds on
"1234 dYn"
Remote Input
Single-pulse remote input
T
3. Present ON and OFF
Conditions.
Method
Action
Result
SET
Button
Present ON and OFF
conditions
Display: Red - Signal Level; Green -
Threshold
Remote Input
Present ON and OFF
conditions
8 SET
Button:
0.04 seconds
≤
"Click"
≤
0.8 seconds
9 Remote Input: 0.04 seconds
≤
T
≤
0.8 seconds
DF-G3 Long Range Expert
™
Dual Display Fiber
Amplifier
18