Item
Model No.
Description
3
DX80N...
Nodes or FlexPower Nodes
4
BWA-E2M
Ethernet Cable, M12 Industrial/RJ45, Straight, 2 m
5
Ethernet hub or switch box
* If I/O is needed on the GatewayPro, use DX85 Modbus RTU Remote I/O devices similar to a previous configuration.
Data Radios
Data Radios
Data radios extend the range of the Modbus network while keeping the network addressing system simple.
In this basic example, the data radios act as a wire replacement to extend the Modbus network.
1. Fieldbus connection
2. Data radio
3. Modbus master device
4. Modbus slave device
Data Radios with DX85 Modbus RTU Remote I/O Devices
In this example network, DX85 Extended Remote I/O devices are wired to the data radios and act as Modbus master or slave devices.
The data radios extend the range of the Modbus network.
1. Fieldbus connection
2. DX85 as Modbus master
3. Data radio
4. DX85 as Modbus slave
Data Radios with a Gateway as the Modbus Master
In this example network, a Gateway is both the master for the radio network consisting of Nodes and the master for the Modbus network.
SureCross Wireless I/O Network Manual
66
www.bannerengineering.com - tel: 763-544-3164
rev. I