background image

4-pin M12 D-code to RJ45 Shielded Ethernet

Model

Length

Style

Dimensions

Pinout (Male)

STP-M12D-406

1.83 m (6 ft)

Straight

47.4 Typ.

ø 14.5

M12 x 1.0 - 6g

RJ45

 

 

1 = White/

Orange
2 = Orange
3 = White/

Blue
6 = Blue

 

4

2

3

1

 

1 = White/

Orange
2 = White/

Blue
3 = Orange
4 = Blue

STP-M12D-415

4.57 m (15 ft)

STP-M12D-430

9.14 m (30 ft)

SMBR90S

Stainless steel bracket

4x M4-07 pemnuts (B)

Includes 2x M4 stainless

steel hex head screws

and flat washers

Hole center spacing:

 A = 40, B =

20

Hole size:

 A = ø 5

A

B

74

10.1

24

8.6

Power Supplies

PSD-24-4

—DC Power Supply, Desktop style, 3.9 A, 24 V DC, Class 2, 4-pin M12/Euro-style quick disconnect (QD)

PSDINP-24-06

—DC power supply, 0.63 Amps, 24 V DC, with DIN Rail Mount, Class I Division 2 (Groups A, B, C, D)

Rated

PSDINP-24-13 

—DC power supply, 1.3 Amps, 24 V DC, with DIN Rail Mount, Class I Division 2 (Groups A, B, C, D)

Rated

PSDINP-24-25 

— DC power supply, 2.5 Amps, 24 V DC, with DIN Rail Mount, Class I Division 2 (Groups A, B, C, D)

Rated
PSW-24-1—DC power supply with multi-blade wall plug, 100–240 V AC 50/60 Hz input, 24 V DC 1 A output, UL Listed

Class 2, 4-pin female M12 connector
PSWB-24-1—DC power supply with multi-blade wall plug,100–240 V AC 50/60 Hz input, 24 V DC 1 A output, UL Listed

Class 2, barrel jack connector

DXMR90-4K IO-Link Master

 

 

26

www.bannerengineering.com - Tel: + 1 888 373 6767

 

Summary of Contents for DXMR90-4K

Page 1: ...DXMR90 4K IO Link Master Instruction Manual Original Instructions 229492 Rev A 9 September 2022 Banner Engineering Corp All rights reserved 229492...

Page 2: ...to use Authentication 21 5 1 1 Set the Web Services to Use Authentication 21 5 1 2 Controller Configuration Authentication 22 5 2 Register Flow and Configuration 22 5 2 1 Basic Approach to Configurat...

Page 3: ...n properties and other details The IODD files for Banner IO link devices can be downloaded for free on www bannerengineering com 1 1 IO Link Systems At least one IO Link master and one IO Link device...

Page 4: ...t The IO Link port functions as a standard digital output 4 DO_C Q 1 3 Combining IO Link Devices with Different Specifications Any combination of masters and devices is possible However if IO Link dev...

Page 5: ...signals using pin 2 or pin 4 of the IO link master ports The configurable IO link master works with IO link devices and allows for quick deployment of IO link data to Ethernet IP and Modbus TCP and Mo...

Page 6: ...es for external devices on the network Wired Connectivity Ethernet Modbus TCP client server or Ethernet IP User Interface API Interface Host Initiated control and Web service integration 2 1 Models Mo...

Page 7: ...concurrently with Modbus TCP By default the DXMR90 4K is configured as a Modbus TCP IP Server 2 3 Dimensions All measurements are listed in millimeters unless noted otherwise Figure 2 DXMR90 4K dimens...

Page 8: ...Link Master Ports 1 4 female Table 1 Ports 1 4 female connector Port 1 4 5 pin M12 Connector female Pin Wire Color Description 2 3 4 1 5 1 Brown bn 18 V DC to 30 V DC 2 White wh I Q digital in out 3...

Page 9: ...Config File The configuration software creates an XML file that is transferred to the DXM using an Ethernet connection The DXM can also receive the XML configuration file from a Web server using an E...

Page 10: ...with the selected model you will be prompted to either proceed and wipe out the active configuration or cancel the model change and preserve the configuration Figure 5 Opening splash screen for Tradi...

Page 11: ...ify a range of registers from the Local Registers Local Registers in Use Modify Multiple Registers screen Select which parameter fields to modify Most parameters have three selections Unchanged no cha...

Page 12: ...load it to the device Changes to the XML file are not automatically saved Save your configuration file before exiting the tool and before sending the XML file to the device to avoid losing data If you...

Page 13: ...ON Do not overtighten the DXMR90 4K s mounting screw during installation Overtightening can affect the performance of the DXMR90 4K DXMR90 4K IO Link Master www bannerengineering com Tel 1 888 373 676...

Page 14: ...IO Link port The DXMR90 4K IO Link Master has 4 Class A ports Pin 2 on these is an additional discrete IO channel For specific pinout connections see Wiring on page 8 For more information on the devi...

Page 15: ...maintained when power is turned off This register data is stored in a data flash component that has a limited write capability of 100 000 cycles so these registers should not be used as common memory...

Page 16: ...ber of passthrough errors 22112 Passthrough success streak 23000 Read map success count Read Write maps statistics 24000 Write map success count 25000 Read map timeout count 25000 Write map timeout co...

Page 17: ...he DXMR90 4K has four IO link ports for connecting IO Link devices and digital sensors lights and actuators All ports use a 4 pin M12 female connector to connect to remote devices No additional wiring...

Page 18: ...t The IO Link port functions as a standard digital input 3 DI_C Q Digital Output The IO Link port functions as a standard digital output 4 DO_C Q For more information on the port settings of the DXMR9...

Page 19: ...Software Instruction manual can also be downloaded directly on the product page for the DXMR90 4K 4 5 Connecting to Remote Modbus Devices In addition to the 4 IO link ports the DXMR90 4K has one Modbu...

Page 20: ...nd slave settings include None default odd even space and mark Timeout applies to the Modbus master port and covers the expected time for messages to be sent throughout the wireless network For the DX...

Page 21: ...a pop up box appears with additional instructions Since the data is not stored in the XML configuration file it is hidden from view of the DXM Configuration Software 4 Click on Send Authentication Th...

Page 22: ...egisters I O Base 5 2 1 Basic Approach to Configuration When programming an application in the DXMR90 4K first plan the overall data structure of the Local Registers The Local Registers are the main s...

Page 23: ...Cs p n b_4205242 DXM EIP Config File for DXM Controller with Internal Gateway Models DXM1xx BxR1 DXM1xx BxR3 and DXM1xx BxCxR1 p n 194730 5 3 1 Configuring the Host PLC On the host PLC install the DXM...

Page 24: ...Data AOI when working in conjunction with the IO Link Master AOI is to provide quasi realtime read write access to all IO Link parameter data in the sensor Each Parameter Data AOI is specific to a gi...

Page 25: ...12 ft MQDEC 420RS 6 10 m 20 ft MQDEC 430RS 9 14 m 30 2 ft MQDEC 450RS 15 2 m 49 9 ft MQDEC 403RR 0 9 m 2 9 ft Male Right Angle Female Right Angle 32 Typ 1 26 30 Typ 1 18 14 5 0 57 M12 x 1 31 Typ 32 Ty...

Page 26: ...A 24 V DC Class 2 4 pin M12 Euro style quick disconnect QD PSDINP 24 06 DC power supply 0 63 Amps 24 V DC with DIN Rail Mount Class I Division 2 Groups A B C D Rated PSDINP 24 13 DC power supply 1 3 A...

Page 27: ...Use Only IP65 IP67 NEMA 1 UL Type 1 Operating Conditions 40 C to 70 C 40 F to 158 F 90 at 70 C maximum relative humidity non condensing Storage Temperature 40 C to 80 C 40 F to 176 F Vibration and Mec...

Page 28: ...ces local serial ports local I O ports and local ISM radio devices to the Internet using either a cellular connection or a wired Ethernet network connection In a continuing effort to provide the best...

Page 29: ...n the destination country The Sure Cross wireless products were certified for use in these countries using the antenna that ships with the product When using other antennas verify you are not exceedin...

Page 30: ...WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRADE USAGE This Warranty is exclusive and limited to repair or at the discretion of Banner Engineering Corp replacement IN NO EVENT SH...

Page 31: ...ntication 21 22 C configuration file save 12 upload 12 M modify multiple registers 11 R registers multiple registers 11 S save configuration file 12 U upload configuration file 12 W webserver authenti...

Reviews: