Trip Output Configured
Operating Mode
Required
Event
Reset
Indicator
Status Indicator Zone Indicators
Diagnostic Displays
OSSD
Outputs
Power-up
Apply
power
Off
Single-Flash
Red
All Single-Flash
Red
Scan code flashes 3 times, alternates
then
or
then
Off
Alignment Mode -
Beam 1 Blocked
Pass
internal
tests
Off
Off
Zone 1 Red5
Others Off
Off
Alignment Mode -
Beam 1 Clear
Align
Beam 1
On
Red
Zone 1 Green
Others Red or
Green
Total number of blocked beams
Off
Run Mode - Clear
Align all
beams
On
On or Flashing
Green6
All On Green
Off
Off
On
Run Mode -
Blocked
Beam(s)
blocked
On
Red
Red or Green5
Total number of blocked beams
Off
Noise Detected -
Reset Interface
Flashing
Continues
previous reading
Continues
previous
reading
Noise Detected -
EDM Interface
Continues
previous
reading
Continues
previous reading
Flashing
Lockout
Internal/
external
fault
Off
Flashing Red
All Off
on page
77)
Off
Latch Output Configured
Operating Mode
Required
Event
Reset
Indicator
Status Indicator Zone Indicators
Diagnostic Displays
OSSD
Outputs
Power-up
Apply
power
Off
Single-Flash
Red
All Single-Flash
Red
Scan code flashes 3 times, alternates
then
or
then
Off
Alignment Mode -
Beam 1 Blocked
Pass
internal
tests
Off
Off
Zone 1 Red5
Others Off
Off
Alignment Mode -
Beam 1 Clear
Align
Beam 1
On
Red
Beam 1 Green
Others Red or
Green
Total number of blocked beams
Off
5 If beam 1 is blocked, Zone indicators 2–8 will be Off, because beam 1 provides the synchronization signal for all the beams.
6 Flashing if Reduced Resolution is enabled.
7 If beam 1 is blocked, Zone indicators 2–8 will be Off, because beam 1 provides the synchronization signal for all the beams.
EZ-SCREEN
®
14/30 mm Safety Light Screen
www.bannerengineering.com - Tel: + 1 888 373 6767
53