QDE2R4-8..D Cable Pinout 17
Pin
Color
Description
3
blue (bu)
Ch 2b
4
no connection
5
no connection
6
no connection
7
no connection
8
white (wh)
Ch 2a
8.8.3 Monitoring Series-Connected Positive-Opening Safety
Switches
When monitoring two individually mounted safety switches (as shown in
on page 74), a faulty switch will be
detected if it fails to switch as the guard opens. In this case, the EZ-SCREEN de-energizes its OSSD output and disables its
reset function until the input requirements are met (i.e., the faulty switch is replaced). However, when a series of interlocking
safety switches is monitored by the EZ-SCREEN, the failure of one switch in the system may be masked or not detected at
all .
bn
wh
bu
bk
22 awg
Open
Open
Open
Figure 31. Monitoring positive-opening safety switches on multiple gates.
QDE2R4-8..D Cable Pinout 18
Pin
Color
Description
1
brown (bn)
Ch 1a
2
black (bk)
Ch 1b
3
blue (bu)
Ch 2b
4
no connection
5
no connection
6
no connection
7
no connection
8
white (wh)
Ch 2a
17 Standard 8-pin M12/Euro-style QD cordsets can also be used, although the pin numbers and wire colors must be verified.
18 Standard 8-pin M12/Euro-style QD cordsets can also be used, although the pin numbers and wire colors must be verified.
EZ-SCREEN
®
14/30 mm Safety Light Screen
www.bannerengineering.com - Tel: + 1 888 373 6767
75