Electrical connections are made through M12 (or Euro-style) quick-disconnects. Some emitter models have a 5-pin
connector for power and the Test function. Other emitters and all receivers have an 8-pin connector for power, ground,
inputs, and outputs.
Functions such as Trip/Latch select, Display Invert, Cascading, Fixed Blanking, Reduced Resolution (Floating Blanking),
Scan Code Select, and External Device Monitoring are described in
on page 10. An auxiliary (aux.)
output may be used to signal the state of the OSSDs to a process controller. All models require a supply voltage of +24 V
dc ±15%.
Both emitter and the receiver feature 7-segment diagnostic displays and individual LEDs to provide continuous indication of
operating status, configuration, and error conditions.
Figure 1. EZ-SCREEN: Typical Application
3.3 Appropriate Applications and Limitations
WARNING: Read this Section Carefully Before Installing the System
If all mounting, installation, interfacing, and checkout procedures are not followed properly, the Banner
device cannot provide the protection for which it was designed. The user is responsible for ensuring that
all local, state, and national laws, rules, codes, or regulations relating to the installation and use of this
control system in any particular application are satisfied. Ensure that all legal requirements have been
met and that all technical installation and maintenance instructions contained in this manual are followed.
The user has the sole responsibility to ensure that this Banner device is installed and interfaced to the
guarded machine by Qualified Persons
1
, in accordance with this manual and applicable safety
regulations. Failure to follow these instructions could result in serious injury or death.
The Banner EZ-SCREEN is intended for point-of-operation machine guarding and other safeguarding applications. It is the
user’s responsibility to verify whether the safeguarding is appropriate for the application and is installed, as instructed by
this manual, by a Qualified Person.
The EZ-SCREEN ability to perform its safeguarding function depends upon the appropriateness of the application and upon
its proper mechanical and electrical installation and interfacing to the guarded machine. If all mounting, installation,
interfacing, and checkout procedures are not followed properly, the EZ-SCREEN cannot provide the protection for which it
was designed.
1
A person who, by possession of a recognized degree or certificate of professional training, or who, by extensive knowledge, training and
experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.
EZ-SCREEN
®
14/30 mm Safety Light Screen
www.bannerengineering.com - Tel: + 1 888 373 6767
9