Table 29: iVu Plus Output Values (Modbus/TCP Input or Holding Registers): CUSTOM MAP
04: Read Input Registers or 03: Read Holding Registers
Input REG #
Holding REG #
WORD NAME
DATA TYPE
1
1001
Input ACK Bits (see
Flags
on
page 136) see also Inputs
10001-16
16-bit Integer
2
1002
Status Bits (see
Flags
on page
136) see also Inputs 10017-32
16-bit Integer
3-4
1003-4
Error Code
32-bit Integer
5-6
1005-6
Inspection Number
32-bit Integer
7-8
1007-8
Iteration Count
32-bit Integer
9-10
1009-10
Pass Count
32-bit Integer
11-12
1011-12
Fail Count
32-bit Integer
13-14
1013-14
Missed Triggers
32-bit Integer
15-16
1015-16
Current Inspection Time
Float
17
1017
Sensor Pass/Fail Bits
16-bit Integer
18-30
1018-30
reserved
16-bit Integer
31-53
1031-53
Inspection Name
2-word 20 Unicode
chars
54-55
1054-55
Frame Number
32-bit Integer
56-167
1056-167
Customizable Space (112
registers)
varies by sensor
168-171
1168-71
reserved
16-bit Integer
172
1172
Command Status
16-bit Integer
173
1173
Command Response Int16
16-bit Integer
174-75
1174-75
Command Response Int32
32-bit Integer
176-77
1176-77
Command Response
Float
178-79
1178-79
Command Response ASCII
String Length
16-bit Integer
180-229
1180-229
Command Response ASCII
String Data
100 byte Unicode char array
230-40
1230-40
reserved
16-bit Integer
Configure Custom Industrial Ethernet (IE) Map
Enable the Custom Map by selecting Custom on the drop-down list.
Click on the yellow arrow button to access the Custom IE Map screen. The Custom IE Map screen allows choosing
sensor result data that appears on the customizable space.