Sensor-Specific Data
Data Size
Area Range Maximum
32
‐
bit Integer
Table 49: Blemish Sensor Type ID = 3
Sensor-Specific Data
Data Size
Blemish Count
32
‐
bit Integer
Blemish Minimum Edge Length
32
‐
bit Integer
Blemish Maximum Edge Length
32
‐
bit Integer
Table 50: Match Sensor Type ID = 4
Sensor-Specific Data
Data Size
Match Count
32
‐
bit Integer
Match Minimum Percent
8
‐
bit Integer
Match Maximum Percent
8
‐
bit Integer
Table 51: Sort Sensor Type ID = 5
Sensor-Specific Data
Data Size
Sort Pattern Map
16
‐
bit Integer
Sort Pattern Count
16
‐
bit Integer
Sort Pattern 1 Count
16
‐
bit Integer
Sort Pattern 2 Count
16
‐
bit Integer
Sort Pattern 3 Count
16
‐
bit Integer
Sort Pattern 4 Count
16
‐
bit Integer
Sort Pattern 5 Count
16
‐
bit Integer
Sort Pattern 6 Count
16
‐
bit Integer
Sort Pattern 7 Count
16
‐
bit Integer
Sort Pattern 8 Count
16
‐
bit Integer
Sort Pattern 9 Count
16
‐
bit Integer
Sort Pattern 10 Count
16
‐
bit Integer
Sort Minimum Percent Match
8
‐
bit Integer
Sort Maximum Percent Match
8
‐
bit Integer
The Custom Map Submodule contains a user-defined map of sensor output data. There are six versions with 16, 32, 64,
128, 256, and 512 bytes, depending on the size of the output data.
Table 52: Custom Map Submodule
Submodule
PLC Input Data
PLC Output Data
Name
Ident No.
Name
Type
Name
Type
16-Byte Custom Map
0x00028
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
16-byte OctetString
32-Byte Custom Map
0x00029
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
32-byte OctetString
64-Byte Custom Map
0x00030
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
64-byte OctetString
128-Byte Custom Map
0x00031
Frame number
Unsigned32
Not applicable
Not applicable
User-mapped Sensor Result Data Block
128-byte OctetString
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164
151