Percent Match
Main Menu > Inspection > Sensors > Match > Percent Match
The Percent Match setting adjusts for how closely the inspected part or label matches the reference part or label. The
Percent Match scale is from 0 to 100 where 0 is the most tolerant and 100 is the least tolerant. Move the slider to the left
or to the right.
Rotation Range
Main Menu > Inspection > Sensors > Match > Rotation Range
The Rotation Range sets the expected rotation of parts or labels during an inspection. For example, a value of 45 means
that the part may rotate 45 degrees in either direction from the reference part and still pass. Move the slider from 0 to 180
degrees.
NOTE: The smaller the rotation range, the faster the inspection will run.
Pass Count
Main Menu > Inspection > Sensors > Match > Pass Count
The Minimum Pass Count is the minimum number of parts, labels, or features expected to fall within the specified criteria;
the Maximum Pass Count is the maximum number expected to fall within the specified criteria. These settings are used to
determine the pass or fail result of the inspection.
Timeout
Main Menu > Inspection >Sensors > Match > Timeout
When the sensor type is set as Match or Sort, this screen provides for adjusting the maximum time the inspection is
allowed to execute. A timeout error is reported in the case inspection runs out of time. If this value is set too high, the
sensor can miss triggers while trying to detect a bad pattern.
Sort Menu
The Sort sensor is used to identify and sort up to 10 stored patterns. The menu items in the Sort sensor provide for
managing stored patterns and configuring Sort sensor inspection parameters.
The Sort sensor cannot be added if any other sensors are selected. The Sort menu can only be reached when adding a
sensor.
Saved Patterns
Main Menu > Inspection > Sensors > Sort > Saved Patterns
When configuring a Sort sensor type, there are 10 pattern storage locations available. The Saved Patterns screen is used
to save a taught pattern to an empty pattern storage location or to overwrite an existing pattern. This screen is also where
patterns can be deleted from a storage location, named, or renamed.
Percent Match
Main Menu > Inspection > Sensors > Sort > Percent Match
iVu Plus TG Gen2 Image Sensor
28
www.bannerengineering.com - Tel: 763.544.3164