Sensitivity
Main Menu > Inspection > Motion > Sensitivity
Sensitivity is used to fine-tune how sensitive the sensor is to finding a reference edge. The Sensitivity value helps account
for light variations that might affect how well the sensor detects edges on inspected parts. The Sensitivity scale is from 0
to 100 where 0 means least sensitive and 100 means most sensitive. If set near 0, the sensor will only find very sharp
edges with strong contrast. If set near 100, the sensor will find very dim or blurry edges, and may be unstable due to
noise within the image.
Rotation
Main Menu > Inspection > Motion > Rotation
Rotation can be Enabled or Disabled. Select Enabled if the part can be expected to rotate during the inspection.
5.2.3 Properties Menu
Main Menu > Inspection > Properties
The Properties menu is used to select a Sensor Type and specify an Inspection Name. Additionally, if the Sensor Type is
Match or Sort, an option to define a timeout for the inspection.
Inspection Name
Main Menu > Inspection > Properties > Inspection Name
The Inspection Name screen displays the name of the current inspection. You can edit the name of the inspection here.
Inspection ID
Main Menu > Inspection > Properties > Inspection ID
Click on the dropdown arrow to view a list of IDs assigned to all inspections on this device. Choose any unused ID to
change the ID of this inspection. The original ID will be marked as 'Unused'.
You may also swap the ID of this inspection with another inspection by selecting that inspection on the list.
5.2.4 Stored Inspections
Main Menu > Inspection > Stored Inspections
Stored Inspections is used to manage stored inspections. Management of stored inspections includes adding, deleting, and
specifying which inspection should be defined as the Startup inspection.
iVu Plus TG Gen2 Image Sensor
30
www.bannerengineering.com - Tel: 763.544.3164