The Startup button allows you to select the inspection to use as the startup inspection. The selected inspection will
automatically start after power up.
Delete Inspections
Main Menu > Inspection > Stored Inspections > Delete
The Delete button is used to delete stored inspections. Note that any running inspection, or the inspection marked as the
Startup inspection, cannot be deleted.
Set Name/ID
Main Menu > Inspection > Stored Inspections > Set Name/ID
The Set Name/ID button is used to change the name or ID of an inspection. You can sort the inspections in numeric or
alphabetical order by clicking on the icon beside the Help icon. Click on Name to edit the name of the inspection. Click on
ID to change the ID of the inspection.
5.3 Imager Menu
Main Menu > Imager
The Imager menu icon is on the Main Menu, and lists parameters that affect the characteristics of the captured image. The
Imager menu is used to access the Auto Exposure routine, manually adjust Exposure and Gain, set Trigger and Strobe
options as well as the size of the field of view (FOV).
5.3.1 Auto Exposure
Main Menu > Imager > Auto Exposure
Auto Exposure optimizes the exposure time and gain for the current lighting conditions. Multiple triggers are required to
complete this function.
NOTE: The Auto Exposure option is not available on the Emulator.
5.3.2 Exposure
Main Menu > Imager > Exposure
Exposure is the amount of time the sensor allows light to energize the imager. Increasing the exposure time by moving
the slider to the right allows more light to energize the imager, which brightens the image.
iVu Plus TG Gen2 Image Sensor
32
www.bannerengineering.com - Tel: 763.544.3164