Output Format
Main Menu > System > Communications > Data Export > Output Format
In the Output Format screen, use the drop-down lists to select Start and End Strings as well a Delimiter. In the field at the
bottom of the screen is an example of how the data will look when it is output.
Data Export Advanced
Main Menu > System > Communications > Data Export > Advanced
During the Data and Image export operation, the sensor's output channels might become full. This can occur if the sensor
is producing export data (frames) faster than the data can be exported from the device or faster than the client is reading
the channel export data (due to bandwidth limitations).
This setting affects how the sensor will behave in this situation.
Select 'Hold READY' to ensure that all frames are transmitted. In this case, the READY signal will remain inactive (sensor is
busy) until the new frame has been added to the channel for transmission. Triggers might be missed during this time.
Select 'Do not hold READY' to cause the sensor to discard the new frame if the channel is full and thus activate the READY
signal immediately after the current inspection is complete. In this case, the discarded frames will not be transmitted.
iVu Plus TG Gen2 Image Sensor
46
www.bannerengineering.com - Tel: 763.544.3164