Output 1, 2, and 3
Main Menu > System > Discrete I/O > Output (#)
Output 1, 2, and 3 are setup separately to improve flexibility and simplicity.
Output can be configured for Inspection Pass, Inspection Fail, Sensor Pass, Sensor Fail, Sort Pattern #1, Missed Trigger or
System Error.
•
A Missed Trigger condition occurs when a trigger is received while sensor is busy inspecting the previous image.
This output signal will be set to active state. This signal will be reset up on resetting the 'History' on the statistics
page.
•
A System Error condition occurs when a fatal error is detected on the sensor. This output signal will be set to active
state. This signal can be reset upon resetting the History on the statistics page, or executing a 'ClearSystemError'
command through command channel.
The default setting is Pass and Latched for Output 1. If Pulsed is selected, the default Pulse width is 50 ms.
NOTE: For Latched the signal is active until the results of an inspection cause a change in the signal
output.
When either Sensor Pass or Sensor Fail is selected, additional setting will become available as shown on the following
graphic.
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164
49