7.6.1 Number of Edges
Main Menu > Inspection > Motion > Number of Edges
On the Number of Edges screen, use the radio buttons to select One Edge or Two Edges. If One Edge is selected, motion is
tracked in one direction (by default, horizontally); if Two Edges is selected, motion can be tracked horizontally and
vertically.
7.6.2 Sensitivity
Main Menu > Inspection > Motion > Sensitivity
Sensitivity is used to fine-tune how sensitive the sensor is to finding a reference edge. The Sensitivity value helps account
for light variations that might affect how well the sensor detects edges on inspected parts. The Sensitivity scale is from 0
to 100 where 0 means least sensitive and 100 means most sensitive. If set near 0, the sensor will only find very sharp
edges with strong contrast. If set near 100, the sensor will find very dim or blurry edges, and may be unstable due to
noise within the image.
7.6.3 Rotation
Main Menu > Inspection > Motion > Rotation
Rotation can be Enabled or Disabled. Select Enabled if the part can be expected to rotate during the inspection.
7.7 Configuring Multiple Sensors in the Inspection
Main > Inspection > Sensors > Add Sensor
Some applications require more than one sensor. New sensors can be added after an inspection has been created. Input
parameters for each sensor can be configured individually.
1. Click on Add Sensor to display the list of sensor types that can be added into the inspection.
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164
73