Compact, single-point devices for error-proofing of bin-picking operations
For the latest technical information about this product, including specifications, dimensions, and wiring, see
• Rugged, cost-effective and easy-to-install solutions for error-proofing and
parts-verification applications
• Compact devices are completely self-contained — no controller needed
• Illuminated dome provides a big, easy-to-see green, red or yellow job light
• Push-button and passive-actuation models available
• Choose NPN or PNP output, depending on model
• Fully encapsulated IP67 construction — ideal for use in abusive environ-
ments; rated to IP69K, depending on installation; see specifications
• Immune to ambient light, EMI and RFI interference
• 12 to 30V dc operation
Models
Model
Sensing Mode /
LED
Housing
Range
Cable*
Output***
Job Light
K50RPLPGRYC3QPMA
Polarized retrore-
flective, visible red,
680 nm
50 mm dome
30 mm mount
polycarbonate
2 m
5-pin Euro
PUR pigtail
QD
PNP,
normally
closed
Green/
yellow/
red
K50RPLPGRYC4QPMA
K50APFF50GRYC3QPMA
Fixed field, infra-
red, 880 nm
50 mm cutoff
PNP,
normally
open
K50APFF50GRYC4QPMA
K50APFF100GRYC3QPMA
100 mm cut-
off
K50APFF100GRYC4QPMA
K50APPBGRYC3QPMA
Push button
—
K50APPBGRYC4QPMA
K80APPBGRYC3QPMA
50 mm dome
Flat or DIN- mount
polycarbonate
K80APPBGRYC4QPMA
* 5-pin 150 mm Euro-style PUR pigtail QD models are listed. For 2 m (6') PVC cable model, omit suffix “QPMA” from model number (e.g.,
“K50RPLPGRYC3”). For 9 m (30') PVC cable model, replace suffix “QPMA” with “W/30” (e.g., “K50RPLPGRYC3 W/30”). For 150 mm
(6") PVC pigtail with 5-pin Euro-style fitting, replace suffix “QPMA” with “QP” (e.g., “K50RPLPGRYC3QP”).
A model with a QD requires a mating cable (see
on page 4).
** PNP models only are listed. For other output types, contact the Factory.
WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to serious injury
or death. This product does NOT include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A sensor failure or malfunction can cause either an energized or de-ener-
gized sensor output condition.
EZ-LIGHT K50 and K80 Specialty — 3-Color
P/N 137551 rev. A
7/7/2011
0 137551
8