background image

Overview

The solid-state output interfaces to a system controller, which is pre-programmed for a specific sequence of tasks. Mounted in or near
each bin in an assembler’s work station, the sensor job light signals the assembler:

• Which bins contain items to be picked in a given operation; and
• In what order they should be picked.

As the assembler takes a part in sequence, the sensor senses that the part was removed and it sends an output signal to the controller.
The controller then verifies if the correct part was taken and may respond by turning that job light OFF, activating the job light of the next
bin in the sequence.
If multiple parts are to be removed from one bin, the job light may remain ON until the appropriate number of signals is returned to the
controller. If an incorrect part is selected, the control system may be wired to signal an alarm for the assembler and/or a supervisor, or it
may be programmed to interpret the action as a call for parts.

Fixed-field and retroreflective-mode models require no interaction to operate, and so eliminate the hand, wrist, and arm stresses associ-
ated with mechanical push buttons. All models are immune to EMI, RFI, and ambient light interference. The polycarbonate and nylon
housing is capable of absorbing high impact (even at low temperatures) and is resistant to abrasion and to damage by most chemicals.
Its domed construction allows moisture and debris to slide easily off the sensor housing, simplifying maintenance. The 30 mm threaded
base provides easy mounting.

Indicator and Output Behavior

NOTE: "C3" and "C4" models as referenced in the table pertain to a part of the product model number, imme-
diately preceding the QPMA designation.

Sensor Conditions

Job Light

Output Signal

Status

C3 Models

C4 Models

Job input active Hand/pick absent

ON Green

ON Green

OFF

Hand/pick present

ON Yellow

ON Yellow until job input is removed

ON

No job input

Hand/pick absent

OFF

OFF

OFF

Hand/pick present

ON Red

ON Red for 5 seconds after hand/pick is removed

ON

 

 

EZ-LIGHT K50 and K80 Specialty — 3-Color

2

www.bannerengineering.com - tel: 763-544-3164

P/N 137551 rev. A

Summary of Contents for K50RPLPGRYC3QPMA

Page 1: ...0APFF50GRYC3QPMA Fixed field infra red 880 nm 50 mm cutoff PNP normally open K50APFF50GRYC4QPMA K50APFF100GRYC3QPMA 100 mm cut off K50APFF100GRYC4QPMA K50APPBGRYC3QPMA Push button K50APPBGRYC4QPMA K80...

Page 2: ...ll for parts Fixed field and retroreflective mode models require no interaction to operate and so eliminate the hand wrist and arm stresses associ ated with mechanical push buttons All models are immu...

Page 3: ...ime 5 milliseconds ON 500 ms leading edge OFF Power Up Output Delay Time 300 ms Indicators Entire translucent dome provides indicator light Job Pick Green Pick Sensed Yellow Mispick Red Job Light Enab...

Page 4: ...nd quick disconnect mod els NPN Sinking Output Models PNP Sourcing Output Models Wiring Key Pinout 12 30V dc 1 3 2 4 Load Job Light Enable Input Low 1 0V Not Used 5 12 30V dc Job Light Enable Input Hi...

Page 5: ...to ex trude rail T slot SMBAMS30RA Right angle SMBAMS series bracket 30 mm mounting hole Articulation slots for 90 rota tion 12 ga cold rolled stainless steel SMB30MM 12 ga stainless steel bracket wi...

Page 6: ...T 51X51BM Square acrylic target Reflectivity Factor 1 5 Max Temperature 50 C 120 F This target has micro prism geome try Optional brackets are available Replaces reflector BRT 36X40BM BRT 50D Round ac...

Page 7: ...7 60 C 140 F 25 mm 1 wide 2 5 m 100 long BRT THG 2 100 0 7 60 C 140 F 50 mm 2 wide 2 5 m 100 long BRT THG 3 100 0 7 60 C 140 F 75 mm 3 wide 2 5 m 100 long Model Reflectivity Factor Maximum Temperatur...

Page 8: ...Yodogawa Ku Osaka 532 0011 JAPAN Tel 81 6 6309 0411 Fax 81 6 6309 0416 www bannerengineering co jp mail bannerengineering co jp Banner Engineering Int l Incorporated Taiwan Rep Office 8F 2 No 308 Sec...

Reviews: