3.2.1 Models Table
Table 2: EZ-SCREEN LS Basic23 mm Resolution Models
Emitter
Receiver
Pair
Defined Area
Response Time,
Tr (ms)
Recovery Time, Typ, OSSDs OFF to
ON (ms)
Non-sync beam
blocked
All beams
blocked
SLLVE23-350
SLLVR23-350
SLLVP23-350
350 mm
9.1
36
124
SLLVE23-420
SLLVR23-420
SLLVP23-420
420 mm
9.9
40
135
SLLVE23-630
SLLVR23-630
SLLVP23-630
630 mm
12.5
51
175
SLLVE23-910
SLLVR23-910
SLLVP23-910
910 mm
15.9
67
225
SLLVE23-1050
SLLVR23-1050
SLLVP23-1050
1050 mm
17.5
74
249
SLLVE23-1190
SLLVR23-1190
SLLVP23-1190
1190 mm
19.2
82
274
SLLVE23-1260
SLLVR23-1260
SLLVP23-1260
1260 mm
20.1
86
288
SLLVE23-1330
SLLVR23-1330
SLLVP23-1330
1330 mm
20.9
89
300
SLLVE23-1540
SLLVR23-1540
SLLVP23-1540
1540 mm
23.5
101
339
SLLVE23-1820
SLLVR23-1820
SLLVP23-1820
1820 mm
26.9
116
391
3.3 Operating Features
The Banner EZ-SCREEN LS Basic Safety Light Curtain models described in this manual feature several functions
(depending on model).
3.3.1 Trip Output
The System is configured for Trip Output which allows the System to enter Run mode automatically. Other measures must
be taken to prevent a pass-through hazard; see
Reducing or Eliminating Pass-Through Hazards
on page 24 and the
warning below for more information.
The OSSD outputs turn ON after power is applied, and the receiver passes its internal self-test/synchronization and
recognizes that all beams are clear. The Trip Output also automatically resets after all beams are cleared.
WARNING:
•
Use of automatic (trip) or manual (latch) start/restart
•
Failure to follow these instructions could result in a serious injury or death.
•
Applying power to the Banner Engineering device, clearing the defined area, or resetting a latch
condition must not initiate dangerous machine motion. Design the machine control circuitry so that
one or more initiation devices must be engaged to start the machine (a conscious act), in addition
to the Banner Engineering device going into Run mode.
3.3.2 External Device Monitoring (EDM)
The External Device Monitoring (EDM) feature allows the EZ-SCREEN LS Basic to monitor the status of external devices,
such as MPCEs. The choices are 1-channel monitoring or no monitoring. EDM is used when the EZ-SCREEN LS Basic
OSSD outputs directly control the MPCEs or other external devices.
This feature is only available when an 8-conductor interface is used.
3.3.3 Fault Output
The current sourcing (PNP) solid-state output (70 mA maximum) is used for control functions that are not safety related; a
typical use is to signal a lockout (fault) to a programmable logic controller (PLC). Available on both the receiver and emitter,
the output provides a fault signal (lockout = On). Interrupting (blocking) the sensing field is not considered a lockout, so the
Fault Output does not change state.
This feature is available only when an 8-conductor interface is used.