6.5.4 Generic Wiring Diagram—8-pin Receiver and a Smart Device
XS/SC26-2xx
XS2so or XS4so
+24VDC
+24VDC 0VDC
0VDC
SO1a
(SO1 not split)
SO1b
EDM
FSD1
FSD2
Single-Channel
Safety Stop Circuit
Dual-Channel
Safety Stop Circuit
1 - Brown
7 - Green/Yellow
6 - Blue
5 - Black
4 - White
8 - Violet
3 - Orange
2 - Orange/Black
+24 V DC
Scan Code **
Ground
0 V DC
OSSD1
OSSD2
EDM
Fault Output ***
8-pin male
M12
IN1
IN2
** Scan Code 1: Not connected or connected to 0VDC (as shown). Scan Code 2: Connect to 24VDC.
*** Fault Out: Not connected or connect indicator (70 mA maximum) to 0VDC (as shown).
EZ-SCREEN
®
LS Basic Safety Light Curtain
50