Fiber Installation Instructions
Banner Engineering Corp. 9714 Tenth Ave. No., Minneapolis, MN 55441 Telephone: (612) 544-3164 FAX: (612) 544-3213
D12 Series sensors for use
with plastic fiber optic as-
semblies include sensors with
the letters FP in their model
number suffix.
Install the plastic fiber optic assembly(s)
as follows:
1) Prepare the sensor ends of the fibers
(see page 1, bottom).
2) Unlock (slide up) the fiber gripper.
3) Gently insert the prepared plastic fiber
sensor ends into the ports as far as they
will go. Slide the fiber gripper down to
lock.
D12 Series
OMNI-BEAM, MAXI-BEAM,
VALU-BEAM, and Q45 Series
sensors for use with plastic
fiber optic assemblies include
sensors with the letters FP in
their model number suffix.
OMNI-BEAM, MAXI-BEAM, VALU-BEAM, Q45 Series
Install the plastic fiber optic assembly(s)
as follows:
1) Prepare the sensor ends of the fibers
(see page 1, bottom).
2) Loosen the clamp screw on the sensor
face.
3) Follow steps 1-3 in the drawing, right.
MINI-BEAM, ECONO-BEAM
Install the plastic fiber optic assembly(s)
as follows:
1) Prepare the sensor ends of the
fibers (see page 1, bottom).
2) Loosen the clamp screw on the
sensor face.
3) Follow steps 1-3 in the drawing, right.
MINI-BEAM and ECONO-
BEAM sensors for use with
plastic fiber optic assemblies
include sensors with the letters
FP in their model number
suffix.
PC44 Series sensors for use
with plastic fiber optic as-
semblies include sensors with
the letters FP in their model
number suffix.
Install the plastic fiber optic assembly(s)
as follows:
1) Prepare the sensor ends of the fibers
(see page 1, bottom).
2) Raise (liftup) the fiber gripper door.
3) Gently insert the prepared plastic fiber
sensor ends into the ports as far as they
will go. Lower the fiber gripper to
lock.
PC44 Series