background image

Original Instructions
July 25, 2023

p/n: 208795 

Rev. H

208795

Q5X with Dual Discrete Outputs and IO-

Link Quick Start Guide



 

Product Description for the Q5X Dual Discrete

This guide is designed to help you set up and install the 

Q5X Laser Measurement Sensor

. For complete information on programming, perfor­

mance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at 

www.bannerengineering.com

. Search for p/

208794

 to view the Instruction Manual. Use of this document assumes familiarity with pertinent industry standards and practices.

WARNING:

Do not use this device for personnel protection

 

Using this device for personnel protection could result in serious injury or death.

This device does not include the self­checking redundant circuitry necessary to allow its use in personnel safe­

ty applications. A device failure or malfunction can cause either an energized (on) or de-energized (off) output 
condition.

Features 

The 

Q5X Laser Measurement Sensor

 has three major features. 

Q5X

 Features

1

2

3

Display and Indicators

The display is a 4­digit, 7­segment LED. Run mode is the primary view displayed. 

For 2-pt, BGS, FGS, and DYN TEACH modes, the display shows the current distance to the target in centimeters. For Dual TEACH mode, 

the display shows the percentage matched to the taught reference surface. A display value of 

999P

 indicates the sensor has not been 

taught. 

Display in Run Mode 

STB DYN FGS BGS

1

2

Output Indicator

On: The output is on
Off: The output is off

Stability Indicator (STB)

On—Stable signal within the specified sensing range
Flashing—Marginal signal (low excess gain), the target is out­

side the limits of the specified sensing range, or a multiple 
peak condition exists

Off—No target is detected within the specified sensing range

Active TEACH Indicators (DYN, FGS, and BGS)

DYN, FGS, and BGS all off—Two­point TEACH mode select­

ed (default)

DYN on—Dynamic TEACH mode selected
FGS on—Foreground suppression TEACH mode selected
BGS on—Background suppression TEACH mode selected
DYN, FGS, and BGS all on—Dual TEACH mode selected

Two output indicators (amber) 

1. 

Display 

2. 

Buttons 

3. 

Stability Indicator (STB—Green) 

1. 



Active TEACH Indicators

DYN—Dynamic (Amber) 
FGS—Foreground Suppression (Amber) 
BGS—Background Suppression (Amber) 

2. 

© Banner Engineering Corp.

Summary of Contents for Q5X

Page 1: ...icators The display is a 4 digit 7 segment LED Run mode is the primary view displayed For 2 pt BGS FGS and DYN TEACH modes the display shows the current distance to the target in centimeters For Dual...

Page 2: ...adiation exposure Do not attempt to disassemble this sensor for repair A defective unit must be returned to the manufacturer CAUTION Never stare directly into the sensor lens Laser light can damage yo...

Page 3: ...1 2014 as described in Laser Notice No 56 dated May 8 2019 Output 1 0 mW Laser wavelength 640 to 670 nm Pulse Duration for 5 m Models 20 s to 2 ms Pulse Duration for 5 m Models 3 s Installation Senso...

Page 4: ...1 bu 3 wh 2 10 30 V DC CH1 CH2 Load Load Channel 2 as Remote Input bk 4 bn 1 bu 3 wh 2 10 30 V DC CH1 CH2 Load Remote Input 1 4 3 2 NOTE Open lead wires must be connected to a terminal block NOTE The...

Page 5: ...water oil etc may create stray light that may degrade the peak performance of the sensor Blow the window clear using filtered compressed air then clean as necessary using only water and a lint free c...

Page 6: ...SS 9 2 m 30 2 ft M12 x 1 14 5 5 9 14 5 L1 47 4 47 4 M12 x 1 1 Brown 2 White 3 Blue 4 Black 5 Gray 5 Pin Threaded M12 Cordsets with Shield Single Ended Model Length Style Dimensions Pinout Female MQDEC...

Page 7: ...Setup mode and the sensor menu from Run mode by pressing and holding MODE for longer than 2 seconds Use and to navigate through the menu Press SELECT to select a menu option and access the submenus Us...

Page 8: ...July 25 2023 page 8 Q5X with Dual Discrete Outputs and IO Link Quick Start Guide Sensor Menu Map Channel 1 Banner Engineering Corp...

Page 9: ...Q5X with Dual Discrete Outputs and IO Link Quick Start Guide July 25 2023 page 9 Sensor Menu Map Channel 2 Banner Engineering Corp...

Page 10: ...ght ref erence point is a combination of the measured distance and returned signal intensity from the reference target Manual adjustment does not move the taught reference point but pressing increases...

Page 11: ...MIL STD 202G Method 201A Vibration 10 Hz to 55 Hz 0 06 inch 1 52 mm double amplitude 2 hours each along X Y and Z axes with device operating Operating Conditions 10 C to 50 C 14 F to 122 F 35 to 95 re...

Page 12: ...mm at 500 mm at 1000 mm at 2000 mm at 3000 mm 200 0 25 6 3 200 0 25 6 3 920 400 100 25 12 1600 700 200 50 25 3200 1400 400 100 50 Standard excess gain is available in 15 25 and 50 ms re sponse speeds...

Page 13: ...nerengineering com Supply Wiring AWG Required Overcurrent Protection A Supply Wiring AWG Required Overcurrent Protection A 20 5 0 26 1 0 22 3 0 28 0 8 24 1 0 30 0 5 FCC Part 15 Class A This equipment...

Page 14: ...bject separation distance 90 to 6 reflectance for the 2000 mm models Switch Point Distance Background X Y Typical performance curves for the 2000 mm models Minimum Separation Target to Background mm D...

Page 15: ...80 100 6 black 90 white 90 white 90 white Repeatability for 50 ms Response Time Repeatability 50 ms 0 1000 2000 3000 4000 5000 0 Dimension X 2 4 6 8 10 12 14 1 Repeatability in mm inch 6 black 18 Gray...

Page 16: ...LOSSES LOSS OF PROFITS OR ANY INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STA...

Reviews: