5.1 Banner Radar Configuration Software ......................................................................................................................................................... 15
5.2 IO-Link Interface........................................................................................................................................................................................... 15
5.3 Remote Input................................................................................................................................................................................................ 15
5.4 Remote Teach .............................................................................................................................................................................................. 18
5.5 Remote Setup .............................................................................................................................................................................................. 18
5.6 Reset the Sensor to Factory Defaults .......................................................................................................................................................... 20
5.7 Factory Default Settings ............................................................................................................................................................................... 20
Use the Banner Radar Configuration software and PRO-KIT to set up the R-GAGE sensor.
For more information visit
www.bannerengineering.com/us/en/products/sensors/software/radar-configuration.html
.
IO-Link is a point-to-point communication link between a master device and sensor. Use IO-Link to parameterize sensors and
transmit process data automatically.
For the latest IO-Link protocol and specifications, see
.
Each IO-Link device has an IODD (IO Device Description) file that contains information about the manufacturer, article
number, functionality etc. This information can be easily read and processed by the user. Each device can be unambiguously
identified via the IODD as well as via an internal device ID. Download the Q90R's IO-Link IODD package (p/n 237876 for
analog models and p/n 237875 for dual discrete models) from Banner Engineering's website at
.
Banner has also developed Add On Instruction (AOI) files to simplify ease-of-use between the Q90R, multiple third-party
vendors' IO-Link masters, and the Logix Designer software package for Rockwell Automation PLCs. Three types of AOI files
for Rockwell Allen-Bradley PLCs are listed below. These files and more information can be found at
.
Process Data AOIs
—These files can be used alone, without the need for any other IO-Link AOIs. The job of a Process Data
AOI is to intelligently parse out the Process Data word(s) in separate pieces of information. All that is required to make use of
this AOI is an EtherNet/IP connection to the IO-Link Master and knowledge of where the Process Data registers are located
for each port.
Parameter Data AOIs
—These files require the use of an associated IO-Link Master AOI. The job of a Parameter Data AOI,
when working in conjunction with the IO-Link Master AOI, is to provide quasi-realtime read/write access to all IO-Link
parameter data in the sensor. Each Parameter Data AOI is specific to a given sensor or device.
IO-Link Master AOIs
—These files require the use of one or more associated Parameter Data AOIs. The job of an IO-Link
Master AOI is to translate the desired IO-Link read/write requests, made by the Parameter Data AOI, into the format a
specific IO-Link Master requires. Each IO-Link Master AOI is customized for a given brand of IO-Link Master.
Add and configure the relevant Banner IO-Link Master AOI in your ladder logic program first; then add and configure Banner
IO-Link Device AOIs as desired, linking them to the Master AOI as shown in the relevant AOI documentation.
Use the remote input to program the sensor remotely.
The remote input provides limited programming options and is Active High. This can be configured for Active Low in the
Banner Radar Configuration software by changing the Sensor Polarity. For Active High, connect the gray input wire to V+ (10
V DC to 30 V DC), with a remote switch connected between the wire and V+. For Active Low, connect the gray input wire to
ground (0 V DC) with a remote switch connected between the wire and ground.
Configuring a Sensor
Chapter 5
Banner Radar Configuration Software
5.1
IO-Link Interface
5.2
Remote Input
5.3
FINAL DRAFT
Summary of Contents for R-GAGE Q90R
Page 22: ...22 F I N A L D R A F T...
Page 28: ...28 F I N A L D R A F T...