5 Product Support and Maintenance
5.1 Maintenance and Service
Do not use alcoholic cleaning agents.
The SSA-ISD Connect is maintenance-free.
For long-term and trouble-free operation, please periodically check the following points:
• solid fit of all components
• reliable switching function
• if damage occurs, please exchange the relevant components
Liability disclaimer— By breach of the given instructions (concerning the intended use, the safety instructions, the
installation and connection through qualified personnel and the testing of the safety function) manufacturer’s liability
expires.
5.2 Status Indicators
The SSA-ISD Connect with Indication has matching indicators on both sides to allow for installation needs and still provide
adequate indication visibility. Each indicator displays both red and green. When power is applied, both LEDs flash red/
green/off, then turn on in the appropriate state (red or green).
Figure 9. SSA-ISD Connect status indicators
Input Device Status
Indicator
(on both sides)
Rotate 180˚
ISD Status Indicator
(on both sides)
Input Device Status (Two NC Contact Status)
OSSD Inputs
SSA-ISD Connect
Status
OSSD Outputs
Input Device
LED
ISD Status
LED
Run State (closed)
On
Normal
On
Green
Green
Run State (closed)
Off
Normal
Off
Green
Red
Off State (open)
On
Normal
Off
Red
Green
Off State (open)
Off
Normal
Off
Red
Red
x
x
Fault (Volt. Mon)
Off
Red Flashing
Red Flashing
Run State (closed)
On
Fault (OSSD)
On/Off *
Red Flashing
Red Flashing
x
x
Fault (internal)
Off
Red Flashing
Red Flashing
*OSSD Fault Tolerant Mode: OSSDs remain on for 20 minutes then turn off. For more information, see