WARNING:

• Interfacing OSSD Outputs to Machine Inputs
• Failure to properly interface the OSSD Outputs to the guarded machine could result in serious

injury or death.

• To ensure proper operation, the Banner device output parameters and machine input parameters

must be considered when interfacing the Banner device OSSD outputs to machine inputs. Design
the machine control circuitry so that the maximum load resistance value is not exceeded and the
maximum specified OSSD Off-state voltage does not result in an On condition.

External device monitoring (EDM) is a function used to monitor the state of the external, positively guided (mechanically

linked) machine control contacts (Final Switching Devives (FSD) and/or MPCEs). The SSA-ISD Connect does not include the

EDM function. As a result, the SSA-ISD Connect should be used with an external safety monitoring device that monitors the

status of the two SSA-ISD Connect OSSDs and is capable of providing the EDM function.
Examples of appropriate external safety monitoring devices include the Banner SC10-2ro Safety Controller.

WARNING:

• The SSA-ISD Connect does not have external device monitoring (EDM).
• If EDM is required for the application, it must be implemented in the external control.

2.4.1 Fault Tolerant Output Feature

Faults that do not immediately compromise the safe operation of the SSA-ISD Connect (for example safety output to

external potential, crosswire short safety output) result in a delayed switch-off of the safety outputs.
The safety outputs switch off when the error warning exceeds 20 minutes. In case of error warning, the SSA-ISD Connect

will flash the ISD red LED.
Use this fault tolerance feature to run down the machinery in a controlled manner. After fixing the fault, the error message is

confirmed by a voltage reset. The safe outputs enable and allow a restart.
Faults that directly affect the safe operation of the SSA-ISD Connect will immediately cause a lockout condition and the

OSSDs will turn off.

2.5 Wiring

Figure 1. Wiring the SSA-ISD Connect to a panel mount Emergency Stop button

MQDMC-5xx

SSA-ISD-TCA

NC2

NC1

E-Stop Push Button

CH1a - Pin 1 - Brown
CH1b - Pin 2 - White
N/C - Pin 3 - Blue
CH2a - Pin 4 - Black
CH2b - Pin 5 - Gray

SSA-ISD Connect with Indication

 

 

6

www.bannerengineering.com - Tel: + 1 888 373 6767

 

Summary of Contents for SSA-ISD-TCA

Page 1: ...SSA ISD Connect with Indication Instruction Manual Original Instructions 215320 Rev B 1 February 2021 Banner Engineering Corp All rights reserved 215320 ...

Page 2: ... Stops 7 2 5 2 Wire the SSA ISD Connect in a Chain of ISD Interlocks 8 2 5 3 Wiring Additional Power Supplies 9 2 6 Checkout 11 2 7 In Series Diagnostic ISD Information 12 3 Specifications 13 3 1 Dimensions 14 4 Accessories 15 4 1 Cordsets 15 4 2 Adapters and Other Accessories 18 4 3 Safety Controllers 18 4 4 ISD Connect Compatible Devices 18 5 Product Support and Maintenance 20 5 1 Maintenance an...

Page 3: ...oughly familiar with all applicable standards some of which are listed within the specifications Banner Engineering Corp makes no claim regarding a specific recommendation of any organization the accuracy or effectiveness of any information provided or the appropriateness of the provided information for a specific application WARNING Not a safeguarding device Failure to follow these instructions c...

Page 4: ...ily manipulated by an operator to defeat the safety function s for example ensure the operator cannot remove a device from the chain 2 2 Installation Requirements The device is intended for indoor use only and must not be affected by environmental conditions Do not expose the device to excessive shocks and vibrations otherwise the device may be deformed or damaged causing malfunction or operation ...

Page 5: ...nnot be suspended overridden or defeated unless accomplished in a manner of the same or greater degree of safety as the machine s safety related control system that includes the SSA ISD Connect An ISD compatible Banner Safety Controller such as the SC10 2ro provides a series connection of redundant contacts that form protective stop circuits for use in either single channel or dual channel control...

Page 6: ...e Banner SC10 2ro Safety Controller WARNING The SSA ISD Connect does not have external device monitoring EDM If EDM is required for the application it must be implemented in the external control 2 4 1 Fault Tolerant Output Feature Faults that do not immediately compromise the safe operation of the SSA ISD Connect for example safety output to external potential crosswire short safety output result ...

Page 7: ...in 4 Black CH2b Pin 5 Gray 2 5 1 Wire the SSA ISD Connect in a Chain of ISD E Stops When connecting emergency stop units in series simplify the wiring by using special t adapters low cost unshielded four wire double ended cables and the SSA ISD Connect with Indication A configuration of three lighted ISD e stops and a panel mount e stop is shown The SSA EB1PLx 0Dx E stops SI RFD switches and the S...

Page 8: ...2 of the t adapter Connect the female end of the double ended cable to the next series connection t adapter SI RFA TS or the SSA ISD Connect 5 At the end of the line install a terminating plug SI RFA P to properly truncate the system 6 Wire the wired end of the 4 pin M12 cable from step 1 directly to a Safety Monitoring Device such as an ISD enabled Banner Safety Controller model SC10 2roe You may...

Page 9: ...e to the female 4 pin M12 of the t adapter Connect the female end of the double ended cable to the next series connection t adapter SI RFA TS or the SSA ISD Connect 5 At the end of the line install a terminating plug SI RFA P to properly truncate the system 6 Wire the wired end of the 4 pin M12 cable from step 1 directly to a Safety Monitoring Device such as an ISD enabled Banner Safety Controller...

Page 10: ...s an SI RFA TS connector the SI RFA TK cannot be connected to an SSA ISD TCA Figure 7 Option 2 Replace the terminator with a power supply The OSSD1 and OSSD2 wires at power supply 2 must be connected to 24 V DC If available set the power supplies for parallel output 1 E Stops with ISD E Stop without ISD 8 SI RFA TS SI RFA TS SI RFA TS SI RFA TS SI RFA TS Power Safety Monitoring Module 24Vdc 0Vdc O...

Page 11: ... A Designated Person should check the safety point for proper operation physical damage button looseness and excessive environmental contamination This should take place on a periodic schedule determined by the user based on the severity of the operating environment and the frequency of switch actuations Adjust repair or replace components as needed If inspection reveals contamination on the switc...

Page 12: ...tics the following information can be transmitted among others Safety Device Status on off or faulted Under voltages in the series connection chain Attempts to remove a device from the chain Wrong order of devices in the chain At this time this information can be refined using the following interfaces USB Displays device information on the PC requires using the SI RF DM1 or SC10 2roe IO Link Bus i...

Page 13: ...voltage Ue 3 V Protection Sustained short circuit and overload protection thermal digital clocking Test pulse duration 70 us Test pulse rate 1 s Input Device Requirements Accepts two normally closed NC contacts Simultaneity Requirement Three seconds Indication Red 618 nm Green 525 nm Housing connectors Housing Polyvinyl Chloride PVC Black Connector Nuts Nickel plating on Cu Zn allow Power Up Delay...

Page 14: ...3 1 Dimensions All measurements are listed in millimeters unless noted otherwise SSA ISD Connect with Indication 14 www bannerengineering com Tel 1 888 373 6767 ...

Page 15: ...Length Style Dimensions Pinout Female MQDC1 501 5 0 5 m 1 5 ft Straight 44 Typ ø 14 5 M12 x 1 2 3 4 1 5 1 Brown 2 White 3 Blue 4 Black 5 Gray MQDC1 506 2 m 6 5 ft MQDC1 515 5 m 16 4 ft MQDC1 530 9 m 29 5 ft MQDC1 506RA 2 m 6 5 ft Right Angle 32 Typ 1 26 30 Typ 1 18 ø 14 5 0 57 M12 x 1 MQDC1 515RA 5 m 16 4 ft MQDC1 530RA 9 m 29 5 ft 4 Pin Threaded Male M12 Euro Style Cordsets Single Ended Model Len...

Page 16: ...515 5 04 m 16 5 ft MQDMC 530 9 04 m 29 7 ft MQDMC 506RA 2 m 6 56 ft Right Angle 31 8 mm 1 25 31 mm 1 22 M12X1 Ø13 5 mm 0 53 MQDMC 515RA 5 m 16 4 ft MQDMC 530RA 9 m 29 5 ft 4 Pin Threaded M12 Euro Style Cordsets Double Ended Model Length Style Dimensions Pinout MQDEC 401SS 0 31 m 1 ft Male Straight Female Straight 40 Typ 1 58 ø 14 5 0 57 M12 x 1 44 Typ 1 73 ø 14 5 0 57 M12 x 1 Female 2 3 4 1 Male 1...

Page 17: ...SS 3 66 m 12 ft 5 Pin Threaded M12 Euro Style Cordsets Double Ended Model Length Style Dimensions Pinout Male Pinout Female MQDEC 501RS 0 31 m 1 02 ft Male Right angle Female Straight 44 Typ 1 73 ø 14 5 0 57 M12 x 1 32 Typ 1 26 30 Typ 1 18 ø 14 5 0 57 M12 x 1 1 4 5 3 2 2 3 4 1 5 MQDEC 503RS 0 91 m 2 99 ft 1 Brown 2 White 3 Blue 4 Black 5 Gray MQDEC 506RS 1 83 m 6 ft MQDEC 512RS 3 66 m 12 ft 5 Pin ...

Page 18: ...2d XS26 2d 26 convertible I O and 2 Redundant Solid State Safety Outputs with Display SC26 2e XS26 2e 26 convertible I O and 2 Redundant Solid State Safety Outputs with Ethernet SC26 2de XS26 2de 26 convertible I O and 2 Redundant Solid State Safety Outputs with Display and Ethernet SC10 2roe 10 Inputs 2 redundant relay safety outputs 3 contacts each ISD compatible 4 4 ISD Connect Compatible Devic...

Page 19: ... LM40KHE Q5A 4 Limit Switch Metal 2 NC CH1 pin 1 2 CH2 pin 4 5 SI LS83E Q5A 4 Limit Switch Plastic 2 NC CH1 pin 1 2 CH2 pin 4 5 SI LS100F Q5A 4 Limit Switch Plastic 2 NC 1 NO CH1 pin 1 2 CH2 pin 4 5 SI QM90E Q5A 4 Limit Switch Plastic 2 NC CH1 pin 1 2 CH2 pin 4 5 SI HG63FQDL Hinge Stainless Steel 2 NC 1 NO SI HGZ63FQDL Hinge Zinc Diecast 2 NC 1 NO SI HG63FQDR Hinge Stainless Steel 2 NC 1 NO SI HGZ...

Page 20: ...te red or green Figure 9 SSA ISD Connect status indicators Input Device Status Indicator on both sides Rotate 180 ISD Status Indicator on both sides Input Device Status Two NC Contact Status OSSD Inputs SSA ISD Connect Status OSSD Outputs Input Device LED ISD Status LED Run State closed On Normal On Green Green Run State closed Off Normal Off Green Red Off State open On Normal Off Red Green Off St...

Page 21: ...ternal error Output fault detected 1 0 A unit in the chain has an output fault and will turn off after the switch off delay period Individual Unit Data Flags Short Name Data Format Description Actuator detected 1 0 Not applicable Wrong actuator detected Input status 1 0 Input devices connect status Sensor not paired 1 0 Not applicable Output 1 1 0 Output 1 is on Output 2 1 0 Output 2 is on Margina...

Page 22: ...les the device has experienced Output switch off time number The delay counter for certain output faults 0 inactive 20 to 1 remaining minutes to device lockout state Range warning count number Not applicable Supply voltage number The actual input voltage detected by the ISD device Internal temperature number The internal temperature of the ISD device C Actuator distance number Not applicable Expec...

Page 23: ...EQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWISE Banner Engineering Corp reserves the right to change modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by...

Reviews: