Radio

General

ETSI/EN: In accordance with EN 300 328: V1.7.1
(2006-05)
IC: 7044A-DX8024

Spread Spectrum Technology

FHSS (Frequency Hopping Spread Spectrum)

Antenna Connection

Ext. Reverse Polarity SMA, 50 Ohms
Max Tightening Torque: 0.45 N·m (4 in·lbf)

Link Timeout

Gateway: Configurable
Node: Defined by Gateway

* With the 2 dB antenna that ships with the product. High-gain an-
tennas are available, but the range depends on the environment
and line of sight. To determine the range of your wireless network,
perform a Site Survey.

DX80 and DX80...C Mounting: #10 or M5 (SS M5 hard-
ware included)
DX80...E Mounting: 1/4-inch or M7 (SS M7 hardware
included)
Max. Tightening Torque: 0.56 N·m (5 in·lbf)

Interface

Indicators: Two bi-color LEDs
Buttons: Two
Display: Six character LCD

Wiring Access

DX80: Four PG-7, One 1/2-inch NPT, One 5-pin Euro-
style male connector
DX80...C: External terminals
DX80...E: Two 1/2-inch NPT

* For European applications, power the DX80 from a Limited Pow-
er Source as defined in EN 60950-1.

Inputs

Outputs

Discrete Input

Rating: 3 mA max current at 30V dc
Sample Rate: 1 second
Report Rate: On change of state

Discrete Input ON Condition

PNP: Greater than 8V
NPN: Less than 0.7V

Discrete Input OFF Condition

PNP: Less than 5V
NPN: Greater than 2V or open

Thermocouple Inputs

Sample Rate: 8 seconds
Report Rate: 32 seconds
Accuracy: 0.1% of full scale r 0.8° C
Resolution: 0.1° C, 24-bit A/D converter

Thermistor (used for CJC)

Model: BWA-THERMISTOR-001
Accuracy: 0.4° C (10 to 50° C); Up to 0.8° C (−40 to
+85° C)
Resolution: 0.1° C, 24-bit A/D converter

Discrete Output

Update Rate: 1 second
ON Condition: Less than 0.7V
OFF Condition: Open

Discrete Output Rating (Performance NMOS)

Less than 1 A max current at 30V dc
ON-State Saturation: Less than 0.7V at 20 mA

Output State Following Timeout

De-energized (OFF)

Environmental

Rating

DX80 models:IEC IP67; NEMA 6; (See UL section be-
low for any applicable UL specifications)
DX80...C models: IEC IP20, NEMA 1
DX80...E models: IEC IP54; NEMA 4

Conditions

Operating Temperature (P3 and P3C models): −40 to
+85° C (Electronics); −20 to +80° C (LCD)
Operating Temperature (P3E model): −40 to +65° C

Shock and Vibration

IEC 68-2-6 and IEC 68-2-7
Shock: 30g, 11 millisecond half sine wave, 18 shocks
Vibration: 0.5 mm p-p, 10 to 60 Hz

Refer to the SureCross

®

 DX80 Wireless I/O Network product

manual, Banner p/n 132607, for installation and waterproofing in-
structions. Operating the devices at the maximum operating condi-
tions for extended periods can shorten the life of the device.

 

 

SureCross Performance FlexPower Node

10

www.bannerengineering.com - tel: 763-544-3164

P/N 155863_web

Rev. C

Summary of Contents for SureCross Performance DX80N9X2S-P3 FlexPower

Page 1: ...te list of accessories refer to Banner Engineering s website www bannerengineering com surecross Models Frequency Power Housing I O DX80N9X2S P3 900 MHz ISM Band 10 to 30V dc or battery supply mod ule...

Page 2: ...its Modbus RTU RS 485 connection is a Modbus slave to a Modbus RTU host controller the wireless network may contain up to 47 Nodes in a single wireless network and the Gateway holds the Modbus regist...

Page 3: ...To access the internal DIP switches follow these steps 1 Unscrew the four screws that mount the cover to the bottom housing 2 Remove the cover from the housing without damaging the ribbon cable or the...

Page 4: ...600 degrees Fahrenheit or 1600 degrees Celsius switch the DIP switch to the ON position and use low resolution mode In high resolution the device cannot store values larger than 1600 Temperature Units...

Page 5: ...OUT x GND Ground dc common connection PWR Power 10 to 30V dc power connection DX80 C Wiring Wiring power to the DX80 C models varies depending the power requirements of the model Terminal Label Gatewa...

Page 6: ...optional 2 RS 485 D1 B RS 232 Tx 3 dc common GND dc common GND 4 RS 485 D0 A RS 232 Rx The BAT connection is a low voltage connection to the internal battery Remove the internal battery if a low volta...

Page 7: ...ocouples are available by configuring the Node Thermocouple Range F Range C Type B 212 to 3 272 F 100 to 1 800 C Type C 32 to 4 208 F 0 to 2 320 C Type E 58 to 1 832 F 50 to 1 000 C Type J 292 to 1 38...

Page 8: ...an integrated battery ship from the factory in storage mode to conserve the battery To wake the device press and hold button 1 for five seconds To put any FlexPower or integra ted battery SureCross r...

Page 9: ...isk of explosion if the battery is re placed incorrectly 4 After replacing the battery allow up to 60 seconds for the device to power up Properly dispose of your used battery according to local regula...

Page 10: ...FF Condition PNP Less than 5V NPN Greater than 2V or open Thermocouple Inputs Sample Rate 8 seconds Report Rate 32 seconds Accuracy 0 1 of full scale reading 0 8 C Resolution 0 1 C 24 bit A D converte...

Page 11: ...the most recent version of any documentation refer to our website www bannerengineering com 2006 2010 Banner Engineering Corp All rights reserved Banner Engineering Corp Limited Warranty Banner Engine...

Reviews: