WARNING:
•
Before applying power to the machine, verify the area is clear.
•
Failure to follow these instructions could result in serious injury or death.
•
Verify the guarded area is clear of personnel and unwanted materials (such as tools)
before applying power to the guarded machine.
WARNING:
•
If the trip test fails, do not use the system.
•
Failure to follow these instructions could result in serious injury or death.
•
If the SX system does not respond properly to the trip test, do not attempt to use the
system. If this occurs, the SX system cannot be relied on to stop dangerous machine
motion when a person or object enters the Safety Zone.
11. Apply power to the guarded machine and verify that the machine does not start up. Interrupt the Safety Zone with the
appropriate test piece (whose size matches the configured resolution) and verify that it is not possible for the guarded
machine to be put into motion while the Safety Zone is interrupted. Repeat for each configured Safety Zone.
12. Initiate the machine cycle or motion of the guarded machine or mobile vehicle. While it is moving, use the appropriate
test piece to interrupt the Safety Zone. Do not attempt to insert the test piece into the dangerous parts of the machine
or directly in the path of the moving vehicle. Upon interrupting the Safety Zone (at any point), verify that:
a)
For stationary applications
: The dangerous parts of the machine come to a stop with no apparent delay.
Remove the test piece from the Safety Zone; verify that the machine does not automatically restart, and that the
initiation device(s) must be engaged to restart the machine.
b)
For mobile applications
: The vehicle stops within the identified/predetermined distance. Remove the test piece
from the Safety Zone; verify that the vehicle does not unintentionally restart, and, if required, that the initiation
device(s) must be engaged to restart the mobile vehicle. This must be accomplished at numerous points along the
entire route (for example, testing each of the Field Pairs in the configuration).
13. Remove electrical power to the SX system. Verify that all OSSD outputs immediately turn off and the machine is not
capable of starting until power is re-applied to the SX system.
14. Test the machine stopping response time, using an instrument designed for that purpose, to verify that it is the same
or less than the overall system response time specified by the machine manufacturer.
15. If the Ethernet cable is removed, ensure the cover is tightly in place.
Do not continue operation until the entire checkout procedure is complete and all problems are corrected.
WARNING:
•
Do not use the machine until the system is working properly.
•
Attempts to use the guarded machine if these checks cannot be verified could result in serious
injury or death.
•
If all these checks cannot be verified, do not attempt to use or operate the machine until the defect
or problem has been corrected.
8.4 Daily Checkout Procedure
Perform the Daily Checkout procedure at every shift change, power-up, and machine set-up change – and at intervals not to
exceed 24 hours during continuous machine run periods. Record a copy of the checkout results and store in the appropriate
place (e.g., near or on the machine, in the machine’s technical file).
Tester: Designated Person or Qualified Person.
Refer to the procedure contained on the Daily Checkout card (Banner p/n
) downloaded from
www.bannerengineering.com. Print out the instructions to be posted near the installation/guarded machine, for easy
reference.
8.5 Semi-Annual Checkout Procedure
Perform the Semi-Annual Checkout procedure every six months following system installation, or whenever changes are
made to the SX configuration or to the machine. A copy of checkout results should be recorded and kept in the appropriate
place (e.g., near or on the machine, in the machine’s technical file).
Tester: Qualified Person.
Refer to the procedure contained on the Semi-Annual Checkout card (Banner p/n
www.bannerengineering.com. Print out the instructions to be posted near the installation/guarded machine, for easy
reference.
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767
103