Figure 73. Scanner window and scatter screen
Window
Scatter
Screen
Contamination
Cleaning Method
Particles, loose, scouring
Vacuum without touching or blow away softly, oil-free; or wipe free in one swipe with cleaning cloth
Particles, loose, non-scouring
Vacuum without touching or blow away softly; or wipe free in one swipe with cleaning cloth
Particles, sticking
Wet with cloth soaked in cleanser; or wipe free in one swipe with cleaning cloth
Particles, statically charged
Vacuum without touching; or wipe free in one swipe with cleaning cloth soaked with cleanser
Particles/drops, smearing
Wet with cloth soaked in cleanser and wipe free in one swipe with cleaning cloth
Water drops
Wipe free in one swipe with cleaning cloth
Oil drops
Wet with cloth soaked in cleanser and wipe free in one swipe with cleaning cloth
Fingerprints
Wet with cloth soaked in cleanser and wipe free in one swipe with cleaning cloth
11.4 Window Replacement
For models that allow the window to be replaced (which is all models except the SX5-B), the following information applies.
When a
Clean Window
error is shown on the device display even after cleaning the window, check for any scratches and/or
spots. If the window is scratched, spotted, or cannot be cleaned to make the unit work (might be micro scratches to the
window reducing its effectiveness), but NOT cracked (which would compromise the IP65 protection of the device), the user
may replace the scanner's window assembly.
Order a replacement window assembly, model
SXA-WIN
. After the replacement is received, carefully follow the instructions
on p. 119. Because of manufacturing variations in the window, perform a scanner
calibration.
CAUTION:
By replacing and calibrating the window, the user acknowledges and accepts the following
terms.
Window replacement is allowed solely when the optical window is scratched, spotted, or in case of unresolvable
Clean
Window
error (no holes or cracks). You are requested to check and comply with this section of the manual, where you can
find all conditions, prerequisites, and terms according to which such procedures shall be performed.
The window replacement procedure allowed provided that:
1. The user's qualified personnel fully comply with the proper instructions set forth in this manual. Instructions are
technical and specific rules that shall be understood, acknowledged, and applied by the user's qualified personnel.
2. Only qualified personnel, as defined below, will perform this procedure.
3. Window replacement is performed in a clean environment that shall be set up in accordance with 'Prerequisites for
Window Replacement' on the following pages to prevent any contamination of the internal optical surfaces.
4. Any dangerous procedure is interrupted, and all safety sensors are disconnected, including any system related to the
scanner.
5. The replacement window is not dirty or scratched and has never been used. Avoid any contamination (dirt,
fingerprints, scratches, etc.) on or inside the new window during installation.
SX Safety Laser Scanner
118
www.bannerengineering.com - Tel: + 1 888 373 6767