3.10.3 Mounting the Protection Bracket
Figure 34. Mounting the SXA-MBK-2 protection bracket to the
scanner
1
2
Bracket Mounted
The
SXA-MBK-2
protection bracket is an optional accessory that
provides protection to the scanner if it is located in an environment
where the scanner may be hit by falling objects or subject to
collision.
Fasten the protection bracket (1) on the back of the scanner using
two M5 screws (2) (maximum of 3 N·m torque). Mount the
SXA-
MBK-2
bracket onto the scanner before installing the other
mounting accessories.
Important:
This protection bracket consumes
the mounting holes on the back of the unit. Use
other holes to mount the scanner to the
machine.
3.10.4 Mounting the Angle Adjustment Brackets
Provide two M5 holes with 73 mm spacing on the intended wall or mounting surface. The M5 UNI 5933 screws used for
mounting the brackets to a wall are not supplied in the bracket mounting kits; they must be supplied by the user.
Pitch and roll angle adjustment bracket (SXA-MBK-1)
—The bracket system is partially assembled.
1. Remove the M4 roll adjustment screws and washers (7), then align the M5 wall mounting screws (9).
2. Mount the roll adjustment bracket (8) to the wall or panel by inserting two M5 UNI 5933 screws (9). Tighten them,
alternating between the two, until they are tight (torque to 2.5 to 3 N·m).
3. Place the assembly of (1) and (6) back onto the roll adjustment bracket (8) (or turn back into place) and re-install the
M4 roll adjustment screws and washers (7). Do not tighten the M4 roll adjustment screws for the roll angle.
If only pitch adjustment is desired, the entire
SXA-MBK-1 can be used with the roll
adjustment centered (level) or the back plates
(6 and 8) can be removed and only the pitch
adjustment bracket (1) is used to mount the
scanner. To remove 6 and 8 first remove the
roll adjustment screws (7) to remove the back
plate (8). Then remove the four screws that
attach (6) to (1) from the back.
The pitch adjustment plate (1) can now be
mounted to the 73 mm spaced holes using the
M5 UNI 5933 screws (9). Tighten the screws,
alternating between the two, until they are
tight (2.5 to 3 N·m torque).
Figure 35. Pitch and roll angle adjustment bracket (SXA-MBK-1)
1
2
3
4
5
6
7
8
Bracket Mounted
9
SX Safety Laser Scanner