Wiring Using a UM Module
Figure 40. Wiring using a UM module
UM-FA-9A
+24 V DC
0 V DC
Fuse
1.6 A
K1
A
6A max.
K2
A
K1
B
6A max.
K2
B
K1
C
6A max.
K2
C
Machine
Control
Circuits
A1
A2
S21
MSC1
Reset
(No Connection)
MSC2 MSC3
S22
S33
S12
S34
13
14
24
33
34
S11
*Arc suppressors
(see WARNING)
MSC1
(No Connection)
(see WARNING)
UM Module Auto Reset
MSC2
MSC3
S33
S34
S11
23
MSC1
*
*
*
MSC2
MSC3
see datasheet
p/n 141249
MSC Monitor
Contacts or
Jumper for No
Monitoring
2 - Brown
8 - Red
7 - Blue
5 - Gray
6 - Pink
3 - Green **
1 - White **
4 - Yellow **
** Functionality of pins 1, 3, and 4 is configured with the GUI
+24 V DC
Functional Earth
0 V DC
OSSD1
OSSD2
Scanner
8-pin Male
Euro-style
face view
WARNING:
•
Properly install arc or transient suppressors
•
Failure to follow these instructions could result in serious injury or death.
•
Install any suppressors as shown across the coils of the machine primary control elements. Do not
install suppressors directly across the output contacts of the safety or interface module. In such a
configuration, it is possible for suppressors to fail as a short circuit.
SX Safety Laser Scanner
54
www.bannerengineering.com - Tel: + 1 888 373 6767