Type
Function
Description
Circuit
AREA SWITCH 5
Muting Enable 1
If high the muting feature is enabled and is
allowed to be performed
+24 V DC
Muting 11
Initiate the muting function if
+24 V DC
Muting 12
engaged with the proper timing
EDM 1
External Device monitoring input for
Need circuit with 2
EDM 2
OSSD 1 and/or OSSD 2
NC contacts to 24 V
Override (single line
pattern)
Forces scanner OSSDs on
+24 V DC
Multi out
Muting Lamp 1
Active muting function signal, supplies 24
VDC to LED lamp
0 V
Warning 1
Output to signal an interruption of a warning
field
0 V
PNP
Warning 2
Alarm 1
Clean window (CLEANW2 code)
0 V
PNP
Alarm 2
Scanner fault (OSSDs off)
Alarm 3
Override on
Safety Output
OSSD 2/1
0 V
PNP
OSSD 2/2
No Function
Not used
Note:
The second set of OSSDs are aligned to the main outputs OSSD1/1 and OSSD1/2 (which are not
configurable) requirements. When a Multi Out pin is selected, a second pin will automatically be configured
(per IEC 61496 requirements). This ensures that two Multi Out outputs are used for the same purpose.
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767
57