Figure 52. Muting function in the X configuration
M1
M2
D
D
Use the T configuration when the SX is mounted vertically and Bidirectional is selected in the configuration. The T
configuration uses four muting sensors. For example, four pairs of opposed-mode or retro-reflective photoelectric sensors or
diffuse photoelectric sensors with background elimination, spaced with two on the inside and two on the outside of the Safety
Zone.
Figure 53. Muting function in the T configuration
M1
M2
M2
M1
D
A
B
D
Use the L configuration when the SX is mounted vertically and Unidirectional is selected in the configuration. This
configuration is suitable for applications requiring unidirectional movement of objects. This configuration uses two mute
sensors (e.g. two pairs of opposed-mode photoelectric sensors) stationed on one side of the Safety Zone. The muting is
initiated when the two sensors are made within the configured maximum muting activation delay time (order does not matter).
The mute cycle ends when the configured time limit is reached after the first mute sensor clears.
SX Safety Laser Scanner
www.bannerengineering.com - Tel: + 1 888 373 6767