6.10 Configure a Static IP Address
To connect a device to the software using the Ethernet TCP/IP interface, match the Ethernet IP Addressing parameters
between the configuration PC and the scanner.
The default scanner static assignment Ethernet IP Address is: 192.168.0.10. The successive IP Address is reserved for
internal scanner functions (for example, 192.168.0.10 and 192.168.0.11 are used by the scanner). If a Master is configured
into a cascade chain with a number of remote scanners, each remote scanner will reserve the next two IP addresses (two
addresses for one remote, four addresses for two remotes, or six addresses for three remotes).
1. Before changing the Ethernet network settings on the PC running the software, close any open applications that use
network resources (email, web browsers, etc).
2. On the PC, go to the
Control Panel
and select
Network and Sharing Center
.
3. Click on the
Local Area Connection
link and open the properties window.
4. Select
Internet Protocol Version 4 (TCP/IPv4)
and open the properties window.
5. Set the
IP address
fields.
For example, set the
IP address
to:
192.168.0.38
(the 38 can be any address other than ones used by a
scanner). Leave the
Subnet mask
to 255.255.255.0.
6. Click
OK
to save.
6.11 Perform a Factory Reset
Perform a factory reset to reset the password, password access control, scanner IP address, and internal configuration back
to the factory (default) settings.
1. Verify that the scanner is selected in the software (displays in the right-hand panel).
2. Go to the
Scanner
>
Settings
>
Factory Reset
menu.
A popup window warns the user that all the devices of a cascade chain (cluster) will be restored to the factory
configuration and the current configuration will be lost.
3. Click
OK
.
A popup window displays.
4. Enter the scanner password (default password 'admin', if it has not been changed).
A popup window informs the user that the operation will take a few minutes and all devices will be restarted.
5. Click
OK
.
After the scanners have been reset back to factory default settings, the
Getting Started
page appears and the
scanner(s) show the
Waiting Configuration
message.
SX Safety Laser Scanner
98