The master or
SX5-B6
scanners can have 1 or 2 Warning Outputs assigned (depending on connector selected, 8 pin can
only have 1 output). These outputs can be assigned to pins or not. The state of the output can also be assigned:
on low
will
turn the output on when the warning field is clear and
on high
will turn the output on when the warning field is blocked.
4.3.5 Alarm Output (All Models Except SX5-B)
These alarm outputs apply to all scanner models except the
SX5-B
model.
One or two alarm outputs can be assigned. These outputs can be assigned to pins for a PNP output.
Enabling Alarm 1 will send a signal when the CLEANW2 warning turns on, signifying that the window needs to be cleaned
(outputs still on).
Enabling Alarm 2 will send a signal when any device fault has turned the outputs off.
4.3.6 Preparing for System Operation
After the initial trip test has been performed (see
on p. 65), and the OSSD safety output connections
have been made to the machine to be controlled, the SX is ready for testing in combination with the guarded machine.
The operation of the SX with the guarded machine must be verified before the combined SX and machine may be put into
For the SX5-B6 and master model, the Warning and Alarm outputs can be accessed via the Ethernet connection instead of
hardwired.
4.4 Wiring Diagrams
4.4.1 Machine Interface Connections for the Stand-alone Models
All connections are made using the 4-pin M12/Euro-style connector on the front of the unit and the 8-pin M12/Euro-style
pigtail on the back of the unit. Ensure that the dust cover is re-installed on the 4-pin M12/Euro-style connector when the
communication cable is not installed.
Figure 38. SX Series Safety Laser Scanner
A
B
A. 4-pin M12/Euro-style connector on the front (for
PC Ethernet connection)
B. Short cable with an 8-pin M12/Euro-style
connection in the back (for machine interface)
The stand-alone models have one OSSD pair and include three configuration signals. These signals allow the user to
configure the scanner with different functions:
•
Signaling when a person or an object is in a Warning Zone
•
Switching the detection areas using external signals (Area Switch)
•
Restarting the device using a Manual reset (restart) and restoring the device after a fault condition (reset)
•
Muting the whole safety area and the single line pattern mute dependent override
•
Signaling when the scanner has entered an alarm condition
SX Safety Laser Scanner