background image

3. Go to the Scanner menu and select Discovery.

The software searches for any scanner connected to the network. The discovered demo kit SX5-B scanner is listed under
the Discovery window with its assigned IP address.

4. Double-click on the information box listing the demo kit SX5-B scanner.

If this is the 

first

 time the scanner is connected to the computer, a warning message appears asking if you want to change

the IP address.

5. Click OK to change the IP address.
6. To match the scanner to the network that the adapter is addressed to (IP Local), change the scanner IP address to

192.168.15.X, where X is a number between 1 and 254, and is not equal to anything else on the subnetwork (subset mask
255.255.255.0).

The scanner uses two IP addresses: the one you assign and the next number up from that address.

7. After changing the scanner's IP address, click OK.

Now that the recognized scanner is 

configured

 to communicate with your laptop, this set of instructions will not need to be

repeated if the software is closed and re-opened.

Demo Kit Example 

Configuration

 #1

This 

configuration

 is a scanner mounted in front of a hazardous machine that should be clear of personnel when in Run Mode. The

configuration

 includes a Warning Zone and assigned warning status output that turns off if the Warning Zone is blocked.

For a simple demonstration, the scanner is set up to use Auto-Reset.

1. Create a new 

configuration.

If the software has just been opened, click New Safety System 

Configuration

.

If you have already established communication, on the menu bar, go to File > New 

Configuration

.

2. On the left side of the screen, double-click on the SX5-B window.
3. In the right corner, click on the right arrow to advance to the next screen.

The 

Configuration

 Settings screen displays.

4. Set the Scenario to Expert. You may also edit the 

configuration

 name, author, description, and the scanner name.

After you enter a scanner name, the name and part number display in the SX5-B window.

5. Click on the right arrow to advance to the next screen.

The Output 

Configuration

 screen displays. Functions that require an output from the SX5 scanner are listed. Grayed-out

fields

 cannot be changed, such as the wires used for OSSD 11 and OSSD 12.

6. In the Output Functions section set the following parameters:

a) Warning: Use the drop-down list to select 1 Warning Zone.
b) Muting: Select Disabled from the drop-down list.

The three selectable I/O wires (white, green, and yellow) are reserved for the needed input and/or output signals. More
complex 

configurations

 that may include Muting inputs, Override input, Reset Input, a Mute Lamp output, as well as one or

two Warning Zone outputs, are not possible without an additional control module or Safety Controller to perform all needed
functions.

7. Click on the right arrow to advance to the next screen.

The Zone Set 

Configuration

 screen displays.

8. From the Zone Set No. drop-down list, select 1.

A Safety Zone with a choice of adding a Warning Zone is considered to be a Zone Set. Having just one Zone Set does not
require the use of the three I/O wires because there is no switching.

When setting up Demo 

Configuration

 3, you will be adding an additional Zone Set, which will require more 

configuration

instructions. There can be up to 6 Zone Sets in one 

configuration.

9. Click on the right arrow to advance to the next screen.

The Input 

Configuration

 screen displays.

10. In the Input Functions section, set the following parameters:

a) Restart Mode: Select Automatic or Manual. For this demonstration, select Automatic.
b) Recovery Time (msec): Select the length of time to recover after resetting. This 

field

 is only available when in Automatic

Restart Mode. For this demonstration, select 200 ms.

c) Muting Type: Select from drop-down list. (Only available if Muting is enabled on the Output 

Configuration

 screen.)

d) Max Muting Activation Delay (msec): Select the delay between M1 and M2, in milliseconds.
e) Timeout min): Set the muting timeout, in minutes.

SX5 Safety Scanner Demo Kit Setup Instructions

 

 

P/N 209666 Rev. A

www.bannerengineering.com - Tel: + 1 888 373 6767

3

Summary of Contents for SX5

Page 1: ...e mating connection located at the top of the I O box 4 Connect the 8 in Euro style connector of the I O Box to the matching connector on the SX5 scanner 5 Plug the power supply into a wall outlet 6 O...

Page 2: ...11 12 Red Object detected in the Safety Zone Green No object is detected in the Safety Zone LED 2 not available LED3 Assigned to Warning Zone 2 Amber Object detected in Warning Zone 2 OFF No object de...

Page 3: ...number display in the SX5 B window 5 Click on the right arrow to advance to the next screen The Output Configuration screen displays Functions that require an output from the SX5 scanner are listed G...

Page 4: ...delete If no icons display click on the small arrow at the top right to view all icons If no Configuration for Zone sets are visible click on the arrow at the top left of the page 16 To create a Warn...

Page 5: ...put to indicate the muting status is active This Demonstration Configuration shows the scanner s ability to perform these functions As shown the SX5 B can be mounted and configured to allow the tray t...

Page 6: ...Example Configuration 3 Two Zone Sets This example application is a scanner mounted in front of a hazardous machine with a small robot inside There is hard guarding surrounding the cell with two small...

Page 7: ...ay is shown on the SX5 then select Accept in the Validation box 15 The SX5 displays a Restart The Monitoring Screen shows the status as Activate and releases the Restart S22 Yellow touch button Show h...

Reviews: