3. Go to the Scanner menu and select Discovery.
The software searches for any scanner connected to the network. The discovered demo kit SX5-B scanner is listed under
the Discovery window with its assigned IP address.
4. Double-click on the information box listing the demo kit SX5-B scanner.
If this is the
first
time the scanner is connected to the computer, a warning message appears asking if you want to change
the IP address.
5. Click OK to change the IP address.
6. To match the scanner to the network that the adapter is addressed to (IP Local), change the scanner IP address to
192.168.15.X, where X is a number between 1 and 254, and is not equal to anything else on the subnetwork (subset mask
255.255.255.0).
The scanner uses two IP addresses: the one you assign and the next number up from that address.
7. After changing the scanner's IP address, click OK.
Now that the recognized scanner is
configured
to communicate with your laptop, this set of instructions will not need to be
repeated if the software is closed and re-opened.
Demo Kit Example
Configuration
#1
This
configuration
is a scanner mounted in front of a hazardous machine that should be clear of personnel when in Run Mode. The
configuration
includes a Warning Zone and assigned warning status output that turns off if the Warning Zone is blocked.
For a simple demonstration, the scanner is set up to use Auto-Reset.
1. Create a new
configuration.
•
If the software has just been opened, click New Safety System
Configuration
.
•
If you have already established communication, on the menu bar, go to File > New
Configuration
.
2. On the left side of the screen, double-click on the SX5-B window.
3. In the right corner, click on the right arrow to advance to the next screen.
The
Configuration
Settings screen displays.
4. Set the Scenario to Expert. You may also edit the
configuration
name, author, description, and the scanner name.
After you enter a scanner name, the name and part number display in the SX5-B window.
5. Click on the right arrow to advance to the next screen.
The Output
Configuration
screen displays. Functions that require an output from the SX5 scanner are listed. Grayed-out
fields
cannot be changed, such as the wires used for OSSD 11 and OSSD 12.
6. In the Output Functions section set the following parameters:
a) Warning: Use the drop-down list to select 1 Warning Zone.
b) Muting: Select Disabled from the drop-down list.
The three selectable I/O wires (white, green, and yellow) are reserved for the needed input and/or output signals. More
complex
configurations
that may include Muting inputs, Override input, Reset Input, a Mute Lamp output, as well as one or
two Warning Zone outputs, are not possible without an additional control module or Safety Controller to perform all needed
functions.
7. Click on the right arrow to advance to the next screen.
The Zone Set
Configuration
screen displays.
8. From the Zone Set No. drop-down list, select 1.
A Safety Zone with a choice of adding a Warning Zone is considered to be a Zone Set. Having just one Zone Set does not
require the use of the three I/O wires because there is no switching.
When setting up Demo
Configuration
3, you will be adding an additional Zone Set, which will require more
configuration
instructions. There can be up to 6 Zone Sets in one
configuration.
9. Click on the right arrow to advance to the next screen.
The Input
Configuration
screen displays.
10. In the Input Functions section, set the following parameters:
a) Restart Mode: Select Automatic or Manual. For this demonstration, select Automatic.
b) Recovery Time (msec): Select the length of time to recover after resetting. This
field
is only available when in Automatic
Restart Mode. For this demonstration, select 200 ms.
c) Muting Type: Select from drop-down list. (Only available if Muting is enabled on the Output
Configuration
screen.)
d) Max Muting Activation Delay (msec): Select the delay between M1 and M2, in milliseconds.
e) Timeout min): Set the muting timeout, in minutes.
SX5 Safety Scanner Demo Kit Setup Instructions
P/N 209666 Rev. A
www.bannerengineering.com - Tel: + 1 888 373 6767
3