RS485 HD Termination Resistance Switch 

 

In Multiplexer applications, enable the termination resistor (ON) ONLY 

on the last device of the chain, the farthest away from the Multiplexer 

(assuming the Multiplexer is the first device of the chain). On all the 

other devices, disable this resistor (OFF). 

 

TCNM-ACBB1 Backup and Restore Module (Accessory) 

The TCNM-ACBB1 Backup and Restore Module (separate accessory) provides configuration parameter 

backup. It can easily be installed by aligning it over its corresponding connector in the TCNM-ACBB1 and 

pushing down until correctly seated. When closed, the plastic support inside the TCNM-ACBB1 cover 

holds the module in place. For further details see the TCNM-ACBB1 manual. 

TCNM-ACBB1 Accessory Mounting 

 

Summary of Contents for TCNM-ACBB1

Page 1: ...through spring clamp terminal blocks inside the TCNM ACBB1 while the reading device is connected to the TCNM ACBB1through a 25 pin connector on the housing A 9 pin connector placed inside the TCNM AC...

Page 2: ...READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT POWER SUPPLY This product is intended to be installed by Qualified Personnel only This device is intended to be supplied by a UL Listed NEC Class 2...

Page 3: ...ous wooden or plastic surfaces using the two self threading screws 3 9 x 45 mm and washers provided in the package Mounting to other surfaces such as concrete walls or metallic panels requires user su...

Page 4: ...tem cabling and switch settings connect the reading device to the 25 pin connector on the TCNM ACBB1 housing Switch ON the TCNM ACBB1 power switch The Power LED turns on blue when the power connection...

Page 5: ...ork Cable Shield Shield to Filtered Earth through the jumper default setting System Wiring The connection and wiring procedure for TCNM ACBB1 is described as follows 1 Open the TCNM ACBB1 by unscrewin...

Page 6: ...on Earth Ground External Trigger Input V Power Source External Trigger I1A External Trigger A polarity insensitive I1B External Trigger B polarity insensitive V Power Reference External Trigger Generi...

Page 7: ...hrough the 25 pin connector This is useful for example to pass power to connected accessories such as Encoder See the relative reading device Reference Manual for details To power TCNM ACBB1 from the...

Page 8: ...ctor pins are listed in the following table TCNM ACBB1 9 pin Female Connector Pinout Pin Name Function 2 TX Auxiliary RS232 3 RX Auxiliary RS232 5 SGND Auxiliary Reference Ground 1 4 6 7 8 9 N C Netwo...

Page 9: ...all the other devices disable this resistor OFF TCNM ACBB1 Backup and Restore Module Accessory The TCNM ACBB1 Backup and Restore Module separate accessory provides configuration parameter backup It ca...

Page 10: ...hrough TCNMACBB1 connected to V V they are not protected from polarity inversion The remaining four LEDs signal activity on the relative I O lines Their meaning depends on the software configuration o...

Page 11: ...to 10 Hz 1 5 mm 13 to 55 Hz 2 g 70 to 200 Hz Shock Resistance EN 60068 2 27 30 g 11 ms 3 shocks on each axis Protection Class EN 60529 IP65 when compression connectors and reading device are correctl...