65
5.3.3 Usage of the steering unit
(1) Install the steering unit
When installing the steering unit, it must ensure concentric with the connecting
shaft, axial clearance can avoid propping by valve core, checking the hand wheel if it
can return to the neutral position flexibly after installing.
The allowable flow rate of the inlet oil pipe is 1-1.5m/s, the allowable flow rate of the
outlet oil pipe is 4-5m/s. The experimental pressure of the high pressure tube must high
than 1.5 times as much as the maximum working pressure.
For the safety and convenient repair, it is suggested that a connector should be
installed at the inlet port of the steering unit for a pressure gauge.
(2) Oil temperature range:-20
℃
~+80
℃
Normal oil tempe30
℃
~+60
℃
(3) Choose oil: N46 or N32 hydraulic oil
(4) Filter oil: The accuracy of oil inputted into the steering unit is 30 micron.
0.2-0.3MPa Back pressure of outlet oil of the steering unit can prevent the oil from
flowing into the oil for the manpower turning.
(5) Cleaning pipes of the system and closed oil tank can reduce the oil pollution.
(6) Trial run: Clean the oil tank and add oil to the top level before trial run. Loose the
bolt connector of the steering cylinder and bleed air at the low speed of the oil pump.
Disassemble the piston rod and steering wheel, turn the hand wheel, make the
piston at the limit left or right position, then add oil into the oil tank to the top level.
Tighten all bolt connectors and connect the piston rod, check the steering system
for the good condition. If the hand wheel can’t be operated flexibly, it’s necessary to find
possible cause and remedy it.
Check the system pressure when the piston of the steering cylinder reaches the
limit position.
(7) Maintenance: Check the condition of the leakage, oil level of the oil tank
everyday. Regularly replace the oil filter and oil. During operation abnormal condition is
found, it’s necessary to find possible cause and remedy it. Don’t turn the hand wheel by
two men at the same time.
Summary of Contents for CPCD 100
Page 1: ...Original instructions ...
Page 25: ...19 4 Lubrication system 5 Capacity chart 6 Inspections before starting ...
Page 32: ...26 Lubrication diagram ...
Page 50: ...44 Fig 2 4 Forward shift clutch Fig 2 5 Reverse shift clutch Fig 2 6 Control valve ...
Page 61: ...55 Fig 4 2 Position of brake pedal ...
Page 99: ...93 Fig 9 1 Principle diagram of electric system domestic CPCD80 100CY ...
Page 100: ...94 Fig 9 2 Principle diagram of electric system imported CPCD80 100W ...
Page 104: ...98 Fig9 5 1 Diagram of meter harness domestic CPCD80 100CY ...
Page 105: ...99 Fig9 5 2 Diagram of meter harness imported CPCD80 100W ...
Page 106: ...100 Fig9 5 3 Diagram of main harness domestic CPCD80 100CY ...
Page 107: ...101 Fig9 5 4 Diagram of main harness imported CPCD80 100W ...
Page 109: ...103 NOTE ...
Page 110: ...104 ...
Page 112: ...106 incurring any obligation ...