January 2022 (v1.5)
14
VARIO W+ OPERATIONS MANUAL
UPPER BURR CARRIER REINSTALLATION:
1. Place the upper burr carrier on top of the grind chamber. It should sit level with the grind
chamber. It will not thread on properly if it is not level.
2. Use the burr removal tool to rotate the upper burr carrier counterclockwise to carefully thread it
into the grind chamber. Threading the upper burr carrier into the grind chamber should be fluid
with minimal resistance. If the upper burr carrier is difficult to rotate, rotate the upper burr carrier
clockwise to free it from the threading, make sure it is level and that the threads on both the grind
chamber and burr holder are free of ground coffee, and try again.
USE OF CLEANING TABLETS
Grinder cleaning tablets are designed to absorb and remove odors and coffee oil residue and should be
considered supplementary to normal cleaning. Grinder cleaning tablets should be the only substance used
to clean the internals of the grinder. Note that cleaning tablets do not take the place of normal cleaning
steps listed above and cannot be used to clear a clog. For grinder tablet cleaning:
1. Remove all beans from the hopper and use the START/STOP
(7)
button to run the grinder to expel
any coffee that remains in the grinder.
2. Adjust the grind setting to 10 and place the recommended amount of the chosen cleaning tablets
into the empty bean hopper. Set the target grind weight equal to or greater than the weight of the
grinder cleaning tablets.
3. Insert the grounds bin, then press the START/STOP button. Grind all the tablets into the bin.
4. Once complete, we recommend grinding approximately 30g coffee (or the recommended amount
in the cleaning tablet instructions) to remove any tablet residue.
5. Discard the ground tablets/coffee.