35
The counter-pressure rubber and the
sealing bar are damaged.
Contact the Technical Support service.
Flashes
.
The pump has absorbed moisture.
Start the DRYING CYCLE.
During a cycle
comes on,
accompanied by an audible signal.
The vacuum is not activated.
The lid has not been closed.
When the cycle has been started, gently
press the lid to activate the vacuum.
The vacuum is not activated.
There is dirt on the seal of the lid.
Clean the tray and the seal.
The vacuum is not activated.
The lid seal is broken.
Contact the Technical Support service for
replacement.
The pump won't start The pump
protection has been activated.
In the bottom right of the packaging
machine, there are 2 buttons (a) that
restore the internal protections.
Press the keys to restore the protections. If
the fault recurs contact the Technical
Support service.
During a cycle with external Container
comes on accompanied by an
acoustic signal.
The lid of the external container is not
positioned correctly.
Correctly position the lid of the external
container.
The external suction device was not
properly connected.
Correctly connect the external suction
device to the packaging machine and to
the container.
It comes on
and
flashes.
Many consecutive cycles were performed
and the oil in the pump has overheated.
Cool the packaging machine for at least 1
hour.
Summary of Contents for 1CSFY