CONNECTION TO THE POWER MAINS 

  

Before making the connection, make cer-

tain  that  the  voltage  and  frequency  indicated  on 
the  data  plate  match  those  of  the  power  supply 
system.

The appliance is supplied with a 90cm-long power cord 
(H05RR-F) on which a 10 A plug must be installed to then 
be connected with a power outlet 

(figure 4a)

.

Alternatively,  the  cable  can  be  connected  directly  to 
the distribution network 

(figure 4b)

: in this case an om-

nipolar disconnecting switch must be provided, with a 
minimum opening of the contacts that allows complete 
disconnection in category III overvoltage conditions.

The  isolating  switch  must  be  located  in  a  position 
which  is  accessible  even  after  the  appliance  is  in-
stalled.
If the appliance is installed together with an oven, the 
connection of the two appliances must be independ-
ent for electrical safety reasons.

 The power cord must 

NOT

:

-   be crushed or rolled up;
-   come into contact with any type of liquid, sharp or hot 

objects or corrosive substances; 

-   reach, at any point, a temperature which is 50°C higher 

than the room temperature;

-   be replaced with a different type of cable 

(see “Technical 

data” on p. 6)

 or with a cable which is not up to standard;

-   be lengthened with extensions.

CONEXIÓN ELÉCTRICA 

   

Antes de la conexión, asegúrese de que 

la tensión y la frecuencia indicadas en la placa de 
características coincidan con las de la instalación 
de alimentación.

El equipo incluye de serie un cable de alimentación 
(H05RR-F) de 90 cm de largo, al que se deberá aplicar 
un  enchufe  capaz  de  soportar  10  A,  que  a  su  vez 
deberá conectarse a una toma de corriente 

(fig. 4a)

.

También se puede conectar el cable directamente a 
la  red  de  distribución 

(fig.  4b)

:  en  este  caso  deberá 

instalarse un dispositivo para la desconexión omnipo-
lar con una separación entre contactos que permita 
la  desconexión  completa  en  las  condiciones  de  la 
categoría III de sobretensión.

Tanto  la  toma  de  corriente  como  el  interruptor 
omnipolar  deben  ser  conformes  a  las  normas  y 
estar instalados en un lugar accesible incluso con 
el equipo empotrado.
Si  se  monta  el  equipo  en  combinación  con  un 
horno,  la  conexión  de  los  dos  equipos  debe  ser 
independiente, por motivos de seguridad eléctrica.

 El cable de alimentación 

NO

 debe:

-   estar aplastado o enrollado sobre sí mismo;
-   entrar en contacto con líquidos de cualquier tipo, 

objetos cortantes o calientes ni sustancias corrosivas; 

-   alcanzar  en  ningún  punto  una  temperatura  que 

supere en 50°C la temperatura ambiente;

-   ser sustituido por otro de distinto tipo 

(véase “Datos 

técnicos”, pág. 6)

  o no conforme a las normas;

-   ser alargado con prolongadores.

10

H05V2V2-F

3x1mm

2

90 cm

10A

B

A

G30 - 28 mbar

220V-240V  50HZ

 0,000 Kw 

G20 - 20 mbar

Questo apparecchio deve essere installato conformemente alle norme in 

vigore e utilizzato solamente in locale ben areato. Consultare il libretto 

istruzioni prima di installare e usare l'aparecchio.

REGOLATO A 

GAS         

G20

N°: XXXXXXXXX

CATEGORIA      II 2H3+            IT

F.lli BARAZZA s.r.l.

MADE IN ITALY

Qn

g/h

00.0 

kW

000  

g/h

XXXXX       
XXXXX       
XXXXX       

MOD
ART

istruzioni prima di installare e usare l aparecchio.

4

Summary of Contents for 1PLB0361TX-00 series

Page 1: ...so Installation and use manual 1PLB0362 00 PLB0362 00 1PLB0361T 00 PLB0361T 00 1PLB0604 00 PLB0604 00 1PLB0904T 00 PLB0904T 00 1PLB0902T 00 PLB0902T 00 1PLB1203T 00 PLB1203T 00 PALBF1203CZI PALBF481CZ...

Page 2: ...Los dibujos los esquemas de ins talaci n y las tablas contenidas en el manual deben considerarse indicativos y nicamente a t tulo informativo Las instalaciones de acometida del edificio deben cumplir...

Page 3: ...eguridad 27 Mantenimiento ordinario 28 Limpieza 28 Periodos de inactividad 29 Eliminaci n al final de la vida til 30 Asistencia postventa 30 DESCRIPTION PAGE TECHNICAL DATA 4 INSTALLATION 7 Safety war...

Page 4: ...270 68 12 382 68 188 270 68 12 mm 65 65 1PLB0604 00 587 80 R 6 R 6 510 360 R 6 510 360 R 6 510 615 R 6 mm mm 90 90 120 120 1PLB1203T 00 1PLBC0902T 00 68 383 68 442 268 12 1150 455 R 6 510 870 421 382...

Page 5: ...40 40 2 5 5 5 1 0 80 mm mm 40 80 80 40 80 80 40 80 80 40 80 480 2 5 5 480 80 7 6 5 1 0 1 6 480 400 80 400 80 7 6 5 480 80 80 2 5 5 480 80 80 80 40 80 80 40 80 80 40 80 PALBF4820ZI PALBF6040ZI PALBF90...

Page 6: ...G20 G25 30 mbar 37 mbar 50 mbar 50 mbar 20 mbar 25 mbar g h 127 g h 127 g h 127 g h 127 l h 158 l h 165 65 65 58 58 96 94 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 1 75 kW 0 45 kW 0 45 kW 0 45 kW 0 4...

Page 7: ...SEGURIDAD Lea detenidamente este manual de instrucciones antes de la instalaci n y o el uso del equipo y cons rvelo en un lugar accesible a todos los usuarios para futuras consultas en caso de traspas...

Page 8: ...er packaging film instructions bag expanded polystyrene impact protections REVISI N Y DESPLAZAMIENTO Tras desembalar el equipo quitando todos los mate riales de embalaje y las pel culas de protecci n...

Page 9: ...campana por encima de la placa de cocci n consulte las instrucciones de montaje de la campana en las que se indica la distancia correcta que se debe dejar AIR AIR AIR 2 INSTALLATION SITE CHOICE Instal...

Page 10: ...n H05RR F de 90 cm de largo al que se deber aplicar un enchufe capaz de soportar 10 A que a su vez deber conectarse a una toma de corriente fig 4a Tambi n se puede conectar el cable directamente a la...

Page 11: ...ientes N L Tierra Sujete el nuevo cable con el sujetacable previsto y vuelva a cerrar la regleta de bornes colocando la tapa en su sitio N L 5 POWER CORD REPLACEMENT Ifnecessary thepowercordcanberepla...

Page 12: ...apretar la tuerca La estanqueidad queda garanti zada por la especial forma de la rampa y por la junta interna A L GJ B G2 UNI CIG 9891 UNI CIG 7129 6 GAS CONNECTION Beforeconnectingtheappliance ensure...

Page 13: ...es burnersandignition consult page 24 Turn gas taps to low flame posi tion and observe stability of the flame regulating the minimum if necessary consult page 14 When satisfied with the hotplate pleas...

Page 14: ...e m nimo no se apaguen los quemadores En caso necesario aumente el caudal de los m nimos ajustando el tornillo de regulaci n 3 4 1 2 MANDOS FRONTALES MANDOS LATERALES FRONT CONTROL PANEL SIDE CONTROL...

Page 15: ...quipo y a la garant a para que la nueva configu raci n sea reconocible y quede documentada 1 2 8 GAS CONVERSION Removetheracks theflamedistributorsandtheburners withthespannerprovided removethenozzles...

Page 16: ...mm mm mm mm Encastre Built in A ras Flush 40 40 65 65 1 2 1 1 mm mm 340 490 595 490 850 490 513 618 595 490 R 7 5 513 873 850 490 R 7 5 mm mm 90 90 513 363 340 490 R 7 5 9A BUILT IN UNIT INSTALLATION...

Page 17: ...17 17 mm mm 90 90 90 90 875 435 458 898 875 435 R 7 5 mm mm 860 490 513 873 860 490 R 7 5 mm mm 120 120 1130 435 458 1153 1130 435 R 7 5 Encastre Built in A ras Flush 1 2 1 1 mm mm 9B...

Page 18: ...los tornillos y las pletinas que se incluyen fig 11 En los equipos realizados seg n especi ficaciones especiales el sistema de fijaci n es personalizado FLUSH PANELS Arrangetheapplianceabovetheembedd...

Page 19: ...r a estar muy caliente tenga cuidado al colocar en este es paciotomasdecorriente otroselectrodom s ticos cables el ctricos tuber as y cualquier material sensible al calor o inflamable SAFETY WARNINGS...

Page 20: ...a toda responsabilidad y no reconoce el derecho de Garant a si no se sigue esta norma FOR COOKING Burn hazard During operation and for a few minutes after use some parts of the appliance reach extreme...

Page 21: ...eato Consultare il libretto istruzioni prima di installare e usare l aparecchio REGOLATO A GAS G20 N XXXXXXXXX CATEGORIA II 2H3 IT F lli BARAZZA s r l MADE IN ITALY Qn g h 00 0 kW 000 g h XXXXX XXXXX...

Page 22: ...cerca de los mandos que indica de manera clara e inequ voca el quemador al que se refiere el mando fig 13A 13B In order to determine which knob controls which cook ingzone consultthevelvettouchscreenw...

Page 23: ...s grasas utilizadas para su fabricaci n Ventile el local USEFUL INFORMATION Before using the appliance for the first time carefully clean the appliance including its com ponents as specified in the Ch...

Page 24: ...mando durante m s tiempo tras el encendido del quemador 24 1 3 2 7 8 9 1 2 5 apagado off MAX MIN 14 USING THE BURNERS Before using the appliance check that the flame distributors 2 the burners 3 and t...

Page 25: ...salirse de la parrilla fig 16 Se proh be utilizar el equipo sin la parrilla o con difusores de calor o reductores distintos de los ofrecidos por el vendedor fig 17 25 OK 15 Flame control 3 Check that...

Page 26: ...cocina Las v lvulas del gas resultan dif ciles de girar Si el equipo no funciona correctamente p ngase en contacto con el servicio t cnico de su zona Monitortheapplianceduringtheentiretime it is in op...

Page 27: ...tacar las superficies forman do antiest ticas marcas que en cualquier caso no afectan al funcionamiento del equipo SAFETY WARNINGS Always disconnect the appliance from the powersupply removetheconnect...

Page 28: ...similares Eloscurecimientodelasparrillasdeacero solo para los modelos que las incluyan es un fe n meno debido al uso normal del equipo y no afecta a sus prestaciones MAINTENANCE SCHEDULE No regular m...

Page 29: ...impie en profundidad el equipo siguiendo las indicaciones del cap tulo correspondiente descon ctelo de la alimentaci n el ctrica y del gas PERIODS OF INACTIVITY Iftheappliancewillnotbeusedforalongperi...

Page 30: ...puestos originales el uso de componentes distintos de los suministrados por el Fabricante anula la Garant a y puede ocasionar da os a las personas y al propio equipo END OF LIFE DISPOSAL Thecrossedbin...

Page 31: ......

Page 32: ...o grafico Artlinea cod PLAB6 rev 03 06 2016 Barazza srl 31025 Sarano di S Lucia di Piave TV ITALIA Via Risorgimento 14 Tel 39 0438 62888 Fax 39 0438 64901 info barazzasrl it www barazzasrl it taste of...

Reviews: