16
BOX 45
Installation instructions
3.4
FITTING THE STOVE
3.4.1
Positioning
The appliance can make use of either a top or rear connection Ø130 mm
for the fl ue
(chimney).
This connection is intended for steel stovepipes, double/single-skinned stainless steel
(insulated) fl ues or double/single-skinned fl exible stainless steel fl ues.
Situate the appliance in such a way that the fl ue gas outlet is precisely in line under the
chimney connection (niche pipe) in the ceiling (top connection) or with the chimney
connection (niche pipe) in the wall (rear connection).
Level off the appliance using the adjustable feet (not for Box with wood log storage
module!). The adjustable feet are accessible from the combustion chamber. To do this
remove the steel sheets on both sides of the grate. Using an Allen key no. 4 to set the
adjustable feet on the correct height.
If the appliance is placed on a natural stone platform, the following must be considered:
- Place the appliance approximately 3 mm above the platform by means of the
adjustable feet.
- The platform must have minimum thickness of 3 cm.
- The platform must support the weight of the appliance directly underneath it.
- Ask your natural stone dealer for additional advice regarding the specifi c type of
stone in combination with the appliance.
When placed on a surface of combustible material, an insulating plate of at least 3 cm
thickness between the appliance and the combustible material must be placed.