30
BOX 67
Installation instructions
8
TECHNICAL DATA
Combustion:
Measured in compliance with
EN 13240 : 2001 and EN 13240 - A2 : 2004
Fuel
Wood
Nominal output
10 kW
Effi ciency
75%
Emissions (dry, at 13% O
2
, 273 K, 1013 hPa):
Carbon monoxide (CO)
0.07%; 905 mg/Nm
3
Dust
19 mg/Nm
3
Total hydrocarbons (C
x
H
y
)
74 mg/Nm
3
Nitrogen oxides (NO
x
)
106 mg/Nm
3
Flue gas mass fl ow
10.5 g/s
Flue temperature
324°C
Chimney draught
0.12 mbar
Flue gas connection
Ø150 mm
Weight
Box
109 kg
Weight
Box with wood log storage
158 kg
module
Inside:
Interior side panels
Heat-resistant panels 1400 kg/m
3
, 1300°C
Interior bottom
Steel (heat-resistant and rust-proof)
Inner lining
Steel (heat-resistant and rust-proof)
Bottom baffl e plate
Heat-resistant panel 2000 kg/m
3
, 1300°C
Top baffl e plate
Stainless steel
Outside:
Construction
Sheet-steel casing.
Doors
Flat door opening to left.
Shutter with fi xed handle.
Operation:
• Handle for opening the door.
• Combustion air supply slider
Single combined slide for controlling the
primary, secondary and tertiary air supply.
Ash collection:
Ashtray with grate.
Combustion air supply:
At least 150 cm
2
opening in the room where
the fi re is located or a outside air supply
opening of Ø125 mm in wall/fl oor.
Summary of Contents for BOX 67
Page 2: ......
Page 6: ...6 BOX 67 Installation instructions...
Page 28: ...28 BOX 67 Installation instructions 7 DIMENSIONS 7 1 BOX 67...
Page 29: ...29 BOX 67 Installation instructions 7 2 BOX 67 WITH WOOD LOG STORAGE MODULE...
Page 33: ...33 BOX 67 Installation instructions...
Page 34: ...34 BOX 67 Installation instructions...
Page 35: ......