An appliance can be ! tted in the newly-built or existing chimney breast of an open ! re.
When ! tting, both ! re safety and operational safety must be safeguarded. The ! tter is
responsible for this.
General guidelines:
If there is a wooden beam above the ! tting location, heat must not radiate directly
onto it. An insulation plate must be hung below the beam, leaving an air gap between
it and the beam of at least 1 cm.
Always use (white) unbound ceramic insulation wool. Bound material (yellow), such
as glass and rock wool, spreads an irritating smell on heating, causes excess smoke
and is unsuitable for high temperatures.
Have any electrical connection for the Perma Air ® convection fan box carried out by
a professional electrician.
Note !
: The fan set should be connected to an earthed wall socket.
This socket must remain accessible at all times.
Before ! tting, remove the door to protect the glass.
Insulation requirements: temperature resistance
³
700°C.
density
³
80 kg/m
3
3.3.1 Positioning of the appliance
The appliance must be positioned on a concrete surface. If such a surface is not imme-
diately available, a suf! ciently solid pedestal of nonin" ammable material should be built
from the creeping space.
The appliance can be placed in position using the carrying brackets (dealer-accessorie)
supplied.
Ventilate the empty space in the chimney, by placing ventilation openings at the top and
bottom of the chimney breast.
The total ventilation openings should be at least 450 cm
2
at the bottom of the chimney
breast and also at least 450 cm
2
at the top of the chimney breast.
(Total ventilation openings: 900 cm
2
.)
Summary of Contents for CUATRO-3 90
Page 2: ......
Page 4: ...4 Cuatro 3 90 Instructions for use...
Page 31: ......
Page 32: ...02 100613 332875 Your Barbas dealer...
Page 34: ......
Page 36: ...4 CUATRO 3 90 Installation instructions...
Page 38: ...6 CUATRO 3 90 Installation instructions...
Page 58: ...26 CUATRO 3 90 Installation instructions Opening of 4 convection air outlets...
Page 101: ...69 CUATRO 3 90 Installation instructions...
Page 102: ...70 CUATRO 3 90 Installation instructions...
Page 103: ......
Page 104: ...01 150613 332965 Uw Barbas dealer...