4.5
Requirements on the concentric flue system
Caution:
• Make sure that no flammable materials are located close to the flue
system. The outer walls of the flue system can be 150 °C.
• Make sure that the concentric flue system is in a casing.
• Make sure that the casing is made of heat resistant material.
• Make sure that air can flow in the casing. Use grates near the floor and
near the ceiling. Do this for every floor where the casing is located.
• Do not insulate the concentric flue.
The parts that are required for the installation of the concentric flue system are numbered
in the illustrations and refer to the part list in
.
Use the universal wall/floor support (number 36 in the part list) to attach the concentric
flue system to the casing and/or the floor.
Floor support
Wall support
Install a concentric flue system as described in this section.
Some configurations of the concentric flue system require the installation of a flue
restriction plate. Different sizes of the flue restriction plate are delivered with the
appliance. Refer to the Installation and maintenance manual.
Requirements
Gas Fire Panorama 110-55
11