7
Troubleshooting
Table 9: Troubleshooting
Problem
possible cause
solution
The main fire stops to burn
The concentric flue system is
not installed according to the
specified instructions.
Install the concentric flue sys-
tem correctly. Refer to the
preparation manual.
An incorrect flue gas restriction
plate is fitted.
Install the correct gas restric-
.
Insufficient pressure of the gas
supply.
Contact your gas supplier com-
pany
The concentric system has a
leak. The leak is possibly on
the inside of the concentric flue.
Check the concentric flue sys-
tem. Refer to the preparation
manual for correct installation.
There is no power supply (230
VAC).
Repair the power supply.
The appliance does not react
on the remote control
The batteries of the remote
control are empty.
Replace the batteries. Refer to
the user manual.
The pilot burner stops to burn
There is insufficient exhaust of
the flue gases.
Check the concentric flue sys-
tem. Refer to the preparation
manual for correct installation.
The pilot burner is dirty.
Clean the pilot burner
The pilot burner is defective.
Replace the pilot burner
The thermocouple is defective
Replace the thermocouple
The light does not operate
The light bulb is defective
Replace the light bulb. See
.
A loud noise occurs in the ap-
pliance
The overpressure door (= glass
front) and overpressure hatch
are activated.
Do a check on the appliance for
problems.
The lacquer of the appliance is
damaged
Use an aerosol can with heat
resistant lacquer to repair any
damage in the laquer.
Troubleshooting
64
Gas Fire Panorama 110-55
Summary of Contents for Panorama 110-55 PF2
Page 1: ...Installation and maintenance manual Gas Fire Panorama 110 55 PF2 Serial number Production date...
Page 50: ...2 Remove the side panels and front panel Maintenance 50 Gas Fire Panorama 110 55...
Page 71: ...9 3 Gas Fire Panorama 110 55 PF2 with 4 cm frame Dimensions Gas Fire Panorama 110 55 71...
Page 73: ...9 5 Gas Fire Panorama 110 55 PF2 with 6 cm frame Dimensions Gas Fire Panorama 110 55 73...
Page 75: ...9 7 Gas Fire Panorama 110 55 PF2 with 10 cm frame Dimensions Gas Fire Panorama 110 55 75...
Page 78: ...9 10 Operating unit Dimensions 78 Gas Fire Panorama 110 55...
Page 81: ...11 EU Declaration of Conformity EU Declaration of Conformity Gas Fire Panorama 110 55 81...
Page 82: ...EU Declaration of Conformity 82 Gas Fire Panorama 110 55...
Page 83: ...EU Declaration of Conformity Gas Fire Panorama 110 55 83...