background image

3

UNILUX-6  70

Instructions for use

1.

Unique identification code of the product-type

2.

Intended use or uses of the construction product, in 
accordance with the applicable harmonised technical 
specification, as foreseen by the manufacturer

3.

Name, registered trade name or registered trade mark 
and contact address of the manufacturer as required 
pursuant to Article 11(5)

4.

Where applicable, name and contact address of the 
authorised representative whose mandate covers the 
tasks specified in Article 12(2)

5.

System or systems of assessment and verification of 
constancy of performance of the construction product 
as set out in Annex V

6.

In case of the declaration of performance concerning a 
construction product covered by a harmonised 
standard

7.

Declared performance

Fire safety

Distance to combustible materials

Minimum distances, in mm
Insulation thickness rear =

100

Insulation thickness sides =

100

Insulation thickness ceiling =

100

Front = 

800

Insulation thickness floor =

100

NPD

Thermal output

Energy efficiency

8.

Signed for and on behalf of the manufacturer by:

Danny Baijens, CEO
(Name and function)

Bladel;  September 18, 2018

………………………………………………………………………..

(place and date of issue)

(Signature)

The performance of the product identified in point 1 is in conformity with the declared performance in point 7.

This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 3.

Water heating output

- kW

Pass

Nominal heat output

10 kW

Room heating output

10 kW

Electrical safety

Pass

Cleanability

Pass

Maximum operating pressure

Not applicable

Flue gas temperature at nominal heat output

T = 319 °C

75.6 %

NPD

Pass

Risk of burning fuel falling out

Pass

Declaration of Performance

According to regulation (EU) 305/2011

No.  1.816.003-2 - CPR-2013/07/01

Unilux-6 70

Room heater without hot water supply

Barbas Bellfires BV; Hallenstraat 17; 5531 AB  Bladel; The Netherlands

Not applicable

System 3

The notified laboratory SGS Nederland BV, No. 0608 performed the 
determination of the product type on the basis of type testing under system 3 
and issued test report EZKA/2015-02/00001-22

Harmonized technical specification

EN13229:2001/A2:2004/AC:2007

Essential characteristics

Performance

CO = 0.07 vol%

Emission of combustion products

Mechanical resistance (to carry a chimney/flue)

Surface temperature

Release of dangerous substances

Pass

Summary of Contents for UNILUX-6 70

Page 1: ...pliance Serial number Production date Barbas wishes you many cosy evenings with your new appliance This document is an essential part of your appliance Read it carefully before use of the appliance an...

Page 2: ......

Page 3: ...Danny Baijens CEO Name and function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in po...

Page 4: ...4 UNILUX 6 70 Instructions for use...

Page 5: ...ions for use CONTENTS Page 1 INTRODUCTION 7 2 SAFETY 8 3 OPERATION 10 4 USING THE APPLIANCE FOR THE FIRST TIME 11 5 USE 14 6 FUEL 21 7 MAINTENANCE 23 8 FREQUENTLY ASKED QUESTIONS 25 9 TECHNICAL DATA 2...

Page 6: ...6 UNILUX 6 70 Instructions for use...

Page 7: ...smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any xed boiler if located in a designated smoke control area It is also an offence to acquire an...

Page 8: ...rous It is not allowed to connect the appliance to a ue which is already connected to another appliance Make sure you know what state your chimney is in Cracks in the chimney may not only lead to damp...

Page 9: ...appliance to burn rubbish Do not use your appliance as a barbecue This can cause ammable fat deposits to be left in the chimney and hastens the chimney becoming clogged Ensure at all times that child...

Page 10: ...nvection set chimney breast convection air 6 Grate 7 Ashtray 8 Inlet opening 2x grate chimney breast ventilation air chimney breast 9 Combustion air supply slider Combined operation for the primary se...

Page 11: ...ated with a lacquer layer resistant to high temperature During the rst hours of operation the burning in of the lacquer may result in an unplea sant smell This is harmless however To speed up the proc...

Page 12: ...eck all available functions before using the appliance for the rst time Check the opening and closing operation of the door Turn the handle all the way down Door is locked Handle forwards The door rel...

Page 13: ...s Check the operation of the slider for the regulation of the combustion air intake middle below the window Check whether the ashtray is completely empty Report any defects immediately to your dealer...

Page 14: ...tart the appliance the chimney is still cold and there is little draught Before the re is lit turn the operating handle completely to the right maximum air supply Open any chimney valve and the valve...

Page 15: ...you can adjust the air supply for further combustion Make sure the appliance burns quietly Note Once you have got the appliance going leave the air supply slider in the centre position for optimal co...

Page 16: ...peci ed in this manual should not be exceeded overloading can cause excess smoke and damage to the appliance Refuelling on to a low re bed If there is insuf cient burning material in the rebed to ligh...

Page 17: ...t may form on the inner side of the window Once the appliance has cooled down this deposit can be removed using glass cleaner or ceramic hob cleaner The appliance may only be positioned in a place whe...

Page 18: ...le if the appliance is equipped with a 45 degrees chimney connection If there is too much ow resistance in the chimney causing insuf cent ow of of the ue gasses one can increase the chimney draught To...

Page 19: ...nce spits out this is a particular problem with softwood from conifers If your oor contains ammable material an extra oor plate is required The appliance must not be operated with the air control or d...

Page 20: ...ractor When the door is open the chimney draws in much more air than is necessary for combustion This relatively cool air cools down the appliance Excessive chimney draught The combustion air does not...

Page 21: ...nce and the environment Paraf n containing open appliance lighters are not suitable for a closed appliance A closed appliance generates more heat than an open appliance thus the paraf n will melt out...

Page 22: ...es average 5 0 The heating value of wood 18 7 MJ kg at 0 humidity is not affected by the sort of wood What does make a difference is the relative humidity of the wood 15 6 MJ kg at 15 humidity Recomme...

Page 23: ...the appliance again Broken ceramic heat resistant glass may not be thrown away in a glass container but must be included in normal household waste Cleaning the appliance Wait for the appliance to cool...

Page 24: ...appliance are not permitted House Ensure that as little dust and as few particles of cigarette smoke candles and oil lamps as possible pollute the air in the room in which the appliance is used Heatin...

Page 25: ...lean wood in the appliance Wood that is too damp immediately gives off lots of ash Make sure the seals are in good working order Any air seeping out around the glass part of the door will cool the air...

Page 26: ...tent of 10 The wood burns up too quickly What should I do Ensure that air cannot get in underneath the fuel Move the combustion air supply slider towards the position The primary air supply is now clo...

Page 27: ...s The combustion of wood involves the following steps Drying The rst step is that the fuel wood dries out Even at low temperatures 100 C any moisture still in the wood will evaporate This drying proce...

Page 28: ...ar Flue gas connection 146 mm 150 mm ext Weight 105 kg Inside Interior side panels Heat resistant panels 1400 kg m3 1300 C Interior bottom Steel heat resistant and rust proof Inner lining Steel heat r...