background image

4

UNILUX-6  265 Left/Right

Instructions for use

1.

Unique identification code of the product-type

2.

Intended use or uses of the construction product, in 
accordance with the applicable harmonised technical 
specification, as foreseen by the manufacturer

3.

Name, registered trade name or registered trade mark 
and contact address of the manufacturer as required 
pursuant to Article 11(5)

4.

Where applicable, name and contact address of the 
authorised representative whose mandate covers the 
tasks specified in Article 12(2)

5.

System or systems of assessment and verification of 
constancy of performance of the construction product 
as set out in Annex V

6.

In case of the declaration of performance concerning a 
construction product covered by a harmonised 
standard

7.

Declared performance

Fire safety

Distance to combustible materials

Minimum distances, in mm
Insulation thickness rear =

100

Insulation thickness sides =

100

Insulation thickness ceiling =

100

Front = 

800

Insulation thickness floor =

100

NPD

Thermal output

Energy efficiency

8.

Signed for and on behalf of the manufacturer by:

Danny Baijens, CEO
(Name and function)

Bladel;  September 18, 2018

………………………………………………………………………..

(place and date of issue)

(Signature)

The performance of the product identified in point 1 is in conformity with the declared performance in point 7.

This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 3.

Water heating output

- kW

Pass

Nominal heat output

9.9 kW

Room heating output

9.9 kW

Electrical safety

Pass

Cleanability

Pass

Maximum operating pressure

Not applicable

Flue gas temperature at nominal heat output

T = 328 °C

75 %

NPD

Pass

Risk of burning fuel falling out

Pass

Declaration of Performance

According to regulation (EU) 305/2011

No.  1.820.001-2 - CPR-2013/07/01

Unilux-6 265 Right

Room heater without hot water supply

Barbas Bellfires BV; Hallenstraat 17; 5531 AB  Bladel; The Netherlands

Not applicable

System 3

The notified laboratory SGS Nederland BV, No. 0608 performed the 
determination of the product type on the basis of type testing under system 3 
and issued test report EZKA/2015-02/00001-25

Harmonized technical specification

EN13229:2001/A2:2004/AC:2007

Essential characteristics

Performance

CO = 0.1 vol%

Emission of combustion products

Mechanical resistance (to carry a chimney/flue)

Surface temperature

Release of dangerous substances

Pass

Summary of Contents for UNILUX-6

Page 1: ...ing appliance Serial number Production date Barbas wishes you many cosy evenings with your new appliance This document is an essential part of your appliance Read it carefully before use of the applia...

Page 2: ......

Page 3: ...by Danny Baijens CEO Name and function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance i...

Page 4: ...by Danny Baijens CEO Name and function Bladel September 18 2018 place and date of issue Signature The performance of the product identified in point 1 is in conformity with the declared performance in...

Page 5: ...structions for use CONTENTS Page 1 INTRODUCTION 7 2 SAFETY 8 3 OPERATION 10 4 USING THE APPLIANCE FOR THE FIRST TIME 11 5 USE 14 6 FUEL 21 7 MAINTENANCE 23 8 FREQUENTLY ASKED QUESTIONS 25 9 TECHNICAL...

Page 6: ...6 UNILUX 6 265 Left Right Instructions for use...

Page 7: ...le or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any xed boiler if located in a designated smok...

Page 8: ...dangerous It is not allowed to connect the appliance to a ue which is already connected to another appliance Make sure you know what state your chimney is in Cracks in the chimney may not only lead t...

Page 9: ...se the appliance to burn rubbish Do not use your appliance as a barbecue This can cause ammable fat deposits to be left in the chimney and hastens the chimney becoming clogged Ensure at all times that...

Page 10: ...tlet opening 2x grill convection set chimney breast convection air 6 Grate 7 Ashtray 8 Inlet opening 2x grate chimney breast ventilation air chimney breast 9 Combustion air supply slider Combined oper...

Page 11: ...is coated with a lacquer layer resistant to high temperature During the rst hours of operation the burning in of the lacquer may result in an unplea sant smell This is harmless however To speed up th...

Page 12: ...USE Check all available functions before using the appliance for the rst time Check the opening and closing operation of the door Turn the handle all the way down Door is locked Handle forwards The do...

Page 13: ...upports Check the operation of the slider for the regulation of the combustion air intake middle below the window Check whether the ashtray is completely empty Report any defects immediately to your d...

Page 14: ...start the appliance the chimney is still cold and there is little draught Before the re is lit turn the operating handle completely to the right maximum air supply Open any chimney valve and the valve...

Page 15: ...slider you can adjust the air supply for further combustion Make sure the appliance burns quietly Note Once you have got the appliance going leave the air supply slider in the centre position for opti...

Page 16: ...se excess smoke and damage to the appliance Refuelling on to a low re bed If there is insuf cient burning material in the rebed to light a new fuel charge excessive smoke emision can occur Refuelling...

Page 17: ...deposit may form on the inner side of the window Once the appliance has cooled down this deposit can be removed using glass cleaner or ceramic hob cleaner Continuous stoking with the primary air supp...

Page 18: ...oo much ow resistance in the chimney causing insuf cent ow of the ue gasses one can increase the chimney draught To do this remove the upper baf e from the appliance and break out with a pair of plier...

Page 19: ...heat in your home less topping up You will also prevent appliance damage from any particles the appliance spits out this is a particular problem with softwood from conifers If your oor contains ammab...

Page 20: ...an extractor When the door is open the chimney draws in much more air than is necessary for combustion This relatively cool air cools down the appliance Excessive chimney draught The combustion air do...

Page 21: ...tack your appliance and the environment Paraf n containing open appliance lighters are not suitable for a closed appliance A closed appliance generates more heat than an open appliance thus the paraf...

Page 22: ...erage 5 0 The heating value of wood 18 7 MJ kg at 0 humidity is not affected by the sort of wood What does make a difference is the relative humidity of the wood 15 6 MJ kg at 15 humidity Per lling fo...

Page 23: ...ay not be thrown away in a glass container but must be included in normal household waste Cleaning the outside The side window is on the outside coated with of the glass a so called heat re ective lay...

Page 24: ...for replacement accessories are available from your BARBAS dealer Use only original parts Modi cations Introduced modi cations to the appliance are not permitted House Ensure that as little dust and...

Page 25: ...at It is the ratio of net capacity and gross capacity How can I keep the glass clean By making a point of using dry clean wood in the appliance Wood that is too damp immediately gives off lots of ash...

Page 26: ...wood the result will be a lot of smoke In both cases the combustion temperature is too low This leaves numerous dangerous compounds intact which means more deposits in your chimney and more waste into...

Page 27: ...gas fan depends on the capacity of the extractor system Always consult your installation engineer about this If the combustion air comes directly from outside via a direct connection If there is cons...

Page 28: ...ecomposition temperature but condense at lower temperatures are often released These are the tar like components this by product is also known as creosote which is deposited in the chimney and cold pa...

Page 29: ...panel Heat resistant panels 1400 kg m3 1300 C Interior bottom Steel heat resistant and rust proof Inner lining Steel heat resistant and rust proof Bottom baf e plate Heat resistant panel 2000 kg m3 13...

Page 30: ...nd claims based on the applicable legal provisions Article 2 Warranty conditions 2 1 Should you wish to claim under the warranty please contact your Barbas dealer 2 2 Complaints should be reported as...

Page 31: ...er parts such as glass glass cord thermocouple and the interior of the combustion chamber a similar guarantee is given until after the rst burning Article 6 Liability 6 1 A claim granted by Barbas Bel...

Page 32: ...04 290319 341937 Your Barbas dealer...